Comparison of trisodium citrate and heparin as catheter-locking solution in hemodialysis patients.

نویسندگان

  • José Luís Bevilacqua
  • Jaelson Guilhem Gomes
  • Vanderson Farley Brito Santos
  • Maria Eugênia Fernandes Canziani
چکیده

INTRODUCTION The high incidence of patients beginning dialysis treatment with venous catheters, as well as the growing number of patients with permanent catheter access, has increased catheter- related blood infections and their consequences. Thus the search for substances with anticoagulant properties that also prevent catheter contamination is necessary. OBJECTIVE This study aimed at comparing heparin and trisodium citrate used as long-term catheter locking solutions regarding the occurrence of pyrogenic reaction, bacteremia, infection- related hospitalizations, thrombosis, and death. METHODS Retrospective study on the infection data from the Infection and Adverse Event Prevention Control Program registry, which included all hemodialysis patients using long-term catheters from April, 2006 to March, 2008. During the first 365 days, catheters were locked with heparin (Heparin group) and, during the following 365 days, with 46.7% trisodium citrate (Citrate group). Sixty-five patients were included in the study using 92 catheters. The groups were compared regarding the occurrence of pyrogenic reaction, bacteremia, hospitalization, catheter thrombosis, and death. RESULTS The catheter-related bacteremia episodes were significantly lower and hospitalization time was significantly shorter in the Citrate group when compared with those in the Heparin group. A tendency towards a lower occurrence of access site infection-related hospitalization was observed in the Citrate group (p = 0.055), and no difference was observed in catheter thrombosis leading to dysfunction between groups. Bacteremia-free and hospitalization-free times were longer in the Citrate group. The occurrence of bacteremia was associated with the presence of diabetes and heparin use. In multivariate analysis, being in the Heparin group was the only factor associated with bacteremia. CONCLUSION The use of 46.7% citrate solution effectively reduced bacteremia episodes and hospitalization in chronic kidney disease patients on hemodialysis with long-term catheters.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Is Taurolidine-citrate an effective and cost-effective hemodialysis cathe-ter lock solution? A systematic review and cost- effectiveness analysis

Background: Prevention of catheter-related infection is of prime importance,. However, because of the risks caused by the leakage of circulating antibiotics and development of resistance to antibiotics, they are replaced by lock solutions. The aim of this study was to evaluate the efficacy and cost- effectiveness of taurolidine-citrate as a hemodialysis catheter lock solution compared to other ...

متن کامل

Reduction of biofilm formation with trisodium citrate in haemodialysis catheters: a randomized controlled trial.

BACKGROUND Formation of an intraluminal microbial biofilm is noted to play a significant role in the development of catheter-related infections (CRIs). Recently, it has been demonstrated that trisodium citrate (TSC) has superior antimicrobial effects over heparin for catheter locking. In this randomized controlled trial, we compared the influence of catheter locking with heparin and TSC on the ...

متن کامل

Randomized, clinical trial comparison of trisodium citrate 30% and heparin as catheter-locking solution in hemodialysis patients.

Interdialytic hemodialysis catheter-locking solutions could contribute to a reduction of catheter-related complications, especially infections. However, they can cause side effects because of leakage from the tip of the catheter. Recently, trisodium citrate (TSC) has been advocated because of its antimicrobial properties and local anticoagulation. In a multicenter, double-blind, randomized, con...

متن کامل

Trisodium citrate 4%--an alternative to heparin capping of haemodialysis catheters.

BACKGROUND Central venous catheters (CVCs) continue to be used at a high rate for dialysis access and are frequently complicated by thrombus-related malfunction. Prophylactic locking with an anticoagulant, such as heparin, has become standard practice despite its associated risks. Trisodium citrate (citrate) 4% is an alternative catheter locking anticoagulant. METHODS The objective was to pro...

متن کامل

Comparison of heparin to citrate as a catheter locking solution for non-tunneled central venous hemodialysis catheters in patients requiring renal replacement therapy for acute renal failure (VERROU-REA study): study protocol for a randomized controlled trial

BACKGROUND The incidence of acute kidney injury (AKI) is estimated at 10 to 20% in patients admitted to intensive care units (ICU) and often requires renal replacement therapy (RRT). ICU mortality in AKI patients can exceed 50%. Venous catheters are the preferred vascular access method for AKI patients requiring RRT, but carry a risk of catheter thrombosis or infection. Catheter lock solutions ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Jornal brasileiro de nefrologia : 'orgao oficial de Sociedades Brasileira e Latino-Americana de Nefrologia

دوره 33 1  شماره 

صفحات  -

تاریخ انتشار 2011