Metallic Fixation of Mandibular Segmental Defects: Graft Immobilization and Orofacial Functional Maintenance

نویسندگان

  • Narges Shayesteh Moghaddam
  • Ahmadreza Jahadakbar
  • Amirhesam Amerinatanzi
  • Mohammad Elahinia
  • Michael Miller
  • David Dean
چکیده

The aim of this study is to investigate the behavior of the healthy mandible under maximum molar bite force to demonstrate the problems associated with the current standard of care procedures for mandibular segmental defect reconstruction (ie, use of Ti-6Al-4V hardware and either a single- or double-barrel fibular graft). With current Ti-6Al-4V mandibular reconstruction hardware, there is a significant stiffness mismatch among the hardware, graft, and the remaining host anatomy. How the distribution of mechanical forces through the mandible is altered after a segmental bone loss and reconstruction is incompletely understood. METHODS We studied a healthy adult mandible for stress, strain, and reaction force distribution during normal mastication. Stress distribution of this model was then used to study problems encountered after mandibular segmental defect reconstructive surgery. We model the use of both single- and double-barrel fibular grafts to repair the loss of the left M1-3 containing segment of the mandible. These simulations were done using 2 sets of plates with different thicknesses. RESULTS We found that the stiffness mismatching between the fixation hardware and the graft and host bone causes stress shielding of that bone and stress concentrations in the fixation hardware and screws. These effects are expected, especially during the bone healing period. However, long term, this abnormal stress-strain distribution may lead to either the hardware's failure due to stress concentration or graft failure due to bone resorption as a result of stress shielding. We found that the stress-strain distribution is more normal with a double-barrel fibular graft. Additionally, we found that thinner fixation plates can reduce stress shielding. CONCLUSION The proposed model can be used to evaluate the performance and optimization of the fixation device.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Curvilinear Segmental Mandibular Reconstruction Utilizing Distraction Osteogenesis and Early Open Callus Manipulation

The authors present a new technique for reconstruction of large curvilinear mandibular defects with distraction osteogenesis and early open callus manipulation. In phase 1, transport disks are created from mandibular bone and distracted across the entire length of the defect, without the restriction from a mandible plate fixation. This allows for full-length distraction until enough regenerate ...

متن کامل

Regenerating Mandibular Bone Using rhBMP-2: Part 1-Immediate Reconstruction of Segmental Mandibulectomies.

OBJECTIVE To describe a surgical technique using a regenerative approach and internal fixation for immediate reconstruction of critical size bone defects after segmental mandibulectomy in dogs. STUDY DESIGN Prospective case series. ANIMALS Dogs (n = 4) that had reconstruction after segmental mandibulectomy for treatment of malignant or benign tumors. METHODS Using a combination of extraor...

متن کامل

Tissue Engineering in Maxillary Bone Defects

BACKGROUND Restoration of craniofacial bone defects has been a concern for oral and maxillofacial surgeons. In this study, the healing effect of fibrin glue scaffold was compared with autologous bone graft in mandibular defects of rabbit. METHODS Bilateral unicortical osteotomy was performed in the diastema region of 10 male Dutch rabbits. The subjects were randomly divided into 2 equal group...

متن کامل

Fixation Release and the Bone Bandaid: A New Bone Fixation Device Paradigm

The current gold standard of care for mandibular segmental defeat reconstruction is the use of Ti-6Al-4V immobilization hardware and fibular double barrel graft. This method is often successful immediately at restoring mandible function, however the highly stiff fixation hardware causes stress shielding of the grafted bone and stress concentration in the fixation device over time which can lead...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 4  شماره 

صفحات  -

تاریخ انتشار 2016