Attenuation Coefficient Estimation Using Equivalent Diffraction Points with Multiple Interface Reflections

نویسندگان

  • T. P. Lerch
  • S. P. Neal
چکیده

The ultrasonic attenuation coefficient of a fluid or solid material is an acoustic parameter routinely estimated in nondestructive evaluation (NDE) and biological tissue characterization. In this paper, a new measurement and analysis technique for estimating the attenuation coefficient as a function of frequency for a fluid or solid is described. This broadband technique combines two established concepts in attenuation coefficient estimation: (1) frequency spectrum amplitude ratios of front surface, first back surface, and second back surface reflections from interfaces of materials with plate-like geometries, and (2) equivalent diffraction points within the transducer wave field. The new approach yields estimates of the attenuation coefficient, reflection coefficient, and material density without the need to make diffraction corrections. This simplifies the overall estimation process by eliminating the transducer characterization step, that is, by eliminating experimental characterization of the effective radius and focal length of the transducer which are required when careful calculated diffraction corrections are applied. In this paper, attenuation coefficient and reflection coefficient estimates are presented for water and three solids with estimates based on measurements made with two different transducers. INTRODUCTION The ultrasonic attenuation coefficient of a medium is an acoustic parameter routinely estimated in nondestructive evaluation (NDE) and biological tissue characterization. Knowledge of the ultrasonic attenuation of a given material is useful to the NDT field inspector searching for flaws in various structural materials, the material scientist characterizing the mechanical properties of the material, and the biologist investigating the acoustic properties of various types of biological tissue. One of the challenges associated with making accurate attenuation coefficient measurements is to separate the energy loss due to absorption and scattering within the medium from other possible sources of energy loss including those due to reflection and transmission at interfaces, diffraction of the transducer's wave field, measurement system inefficiencies, and misalignment of the transducer and specimen. In this paper, we will consider four attenuation coefficient estimation approaches (see Table 1): 1) a Classical Approach driven by the ratio of magnitude spectra from two interface reflections; 2) the Papadakis Approach which eliminates the need to make explicit corrections for reflection CP657, Review of Quantitative Nondestructive Evaluation Vol. 22, ed. by D. O. Thompson and D. E. Chimenti © 2003 American Institute of Physics 0-7354-0117-9/03/$20.0

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Hybrid spectral domain method for attenuation slope estimation.

Attenuation estimation methods for medical ultrasound are important because attenuation properties of soft tissue can be used to distinguish between benign and malignant tumors and to detect diffuse disease. The classical spectral shift method and the spectral difference method are the most commonly used methods for the estimation of the attenuation; however, they both have specific limitations...

متن کامل

Technical Notes and Research Briefs

The basic problem of measuring the angular dependence ofreflection coefficient in solids is the d•culty of steering around the acoustic tmun. Although pure dectronic scanning is posablc too, only some kind of mechanical solution seems to be practicable. As for mechanical scanning, we may choose to movc the transduce• along a curved surface, •$., a cylindrical one, a;ming the beam at the same po...

متن کامل

Estimation of absorbed dose of salivary glands in radioiodine therapy and its reduction using pilocarpine [Persian]

  Introduction:  The use of radioactive iodine (131I) has become an important adjunct to the treatment of thyroid cancer and hyperthyroidism. Salivary gland has the ability to concentrate radioactive iodine under normal circumstances. Salivary gland dysfunction and dry mouth are the common side effectsof high-dose radioiodine therapy. The purposeof this stu...

متن کامل

The evaluation of change in attenuation coefficient of cerrobend block used for radiation protection of healthy tissues in megavoltage photon radiation therapy after multiple melting

Introduction: Protecting the vital organs in radiation therapy is one of the most important issues. Cerrobend alloy, the most common material used as the shield, is melted several times and used for different patients. In this study changes in attenuation coefficient of cerrobend due to melting was investigated.   Materials and Methods: In melting furnace, ...

متن کامل

Validation of computed tomography-based attenuation correction of deviation between theoretical and actual values for four computed tomography scanners

Objective: In this study, we aimed to validate the accuracy of computed tomography-based attenuation correction (CTAC) using the bilinear scaling method.Methods: The measured attenuation coefficient (μm) was compared to a theoretical attenuation coefficient (μt ) using four different CT scanners and an RMI 467 phantom. The effective energy of the CT beam X-rays was calculated, using the aluminu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003