Quantitative methods in the evaluation of thallium-201 myocardial perfusion images.
نویسندگان
چکیده
Methods have been developed for on-line computer enhancement of a scintillation camera's myocardial images and for a graphical presentation showing relative thallium-201 activity in the myocardium. Enhancement uses fast Fourier transform techniques. The methods have been applied to multiple images obtained after stress and 4--5 hr rest. Patients with myocardial infarction and/or transient ischemia were evaluated and typical examples are presented.
منابع مشابه
Serial Myocardial Imaging after a Single Dose of Thallium-201
Although thallium-201 exercise scintigraphy has been established for the detection of myocardial ischemia and viability, little is known regarding the myocardial thallium-201 kinetics during angioplasty. Herein, we report a 77-year old man with angina pectoris, in whom serial myocardial imaging after a single dose of thallium-201 was helpful in identifying not only the culprit lesion and myocar...
متن کاملTc-99m-MIBI in evaluation of myocardial perfusion [Persian]
Tc-99m-MIBI is an isonrtrile derivative used for evaluation of myocardial perfusion in recent years. In this preliminary report, 7 patients with coronary artery disease are evaluated with Tc-99m-MlBl stress planar and sped studies. Good correlation with coronary angiography is observed in these cases. In view of inherent technical problems present with thallium 201, Tc-99m-MIBi is a good ...
متن کاملTemporal Changes in Sequential Quantitative Thallium-201 Imaging Following Myocardial Infarction in Dogs: Comparison of Four and Twenty-Four Hour Infarct Images
Thallium-201 ((201)T1) myocardial perfusion imaging allows definition of zones of myocardial infarction and ischemia. The temporal changes in sequential quantitative (201)T1 infarct imaging was studied 4 and 24 hours in dogs subjected to closed-chest anterior wall myocardial infarction. A temporal decrease in (201)T1 imaged infarct areas was noted in 10 of 13 animals. In no animal did the infar...
متن کاملSerial Myocardial Imaging after a Single Dose of Thallium-201
Although thallium-201 exercise scintigraphy has been established for the detection of myocardial ischemia and viability, little is known regarding the myocardial thallium-201 kinetics during angioplasty. Herein, we report a 77-year-old man with angina pectoris, in whom serial myocardial imaging after a single dose of thallium-201 was helpful in identifying not only the culprit lesion and myocar...
متن کاملCoronary-to-pulmonary artery fistula in adults: Evaluation with thallium-201 myocardial perfusion SPECT
OBJECTIVES With the increasing use of multi-detector CT, the number of detected cases with coronary-to-pulmonary artery fistula (CPAF) has increased. Several previous studies reported severe cases of angina, but no appropriate tests to evaluate myocardial perfusion for patients with CPAF have been established. We evaluated the hemodynamic characteristics of CPAF using thallium-201 (Tl-201) sing...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of nuclear medicine : official publication, Society of Nuclear Medicine
دوره 19 10 شماره
صفحات -
تاریخ انتشار 1978