Assessment of a Microsoft Kinect-based 3D scanning system for taking body segment girth measurements: a comparison to ISAK and ISO standards.
نویسندگان
چکیده
Use of anthropometric data to infer sporting performance is increasing in popularity, particularly within elite sport programmes. Measurement typically follows standards set by the International Society for the Advancement of Kinanthropometry (ISAK). However, such techniques are time consuming, which reduces their practicality. Schranz et al. recently suggested 3D body scanners could replace current measurement techniques; however, current systems are costly. Recent interest in natural user interaction has led to a range of low-cost depth cameras capable of producing 3D body scans, from which anthropometrics can be calculated. A scanning system comprising 4 depth cameras was used to scan 4 cylinders, representative of the body segments. Girth measurements were calculated from the 3D scans and compared to gold standard measurements. Requirements of a Level 1 ISAK practitioner were met in all 4 cylinders, and ISO standards for scan-derived girth measurements were met in the 2 larger cylinders only. A fixed measurement bias was identified that could be corrected with a simple offset factor. Further work is required to determine comparable performance across a wider range of measurements performed upon living participants. Nevertheless, findings of the study suggest such a system offers many advantages over current techniques, having a range of potential applications.
منابع مشابه
Calculating Body Segment Inertia Parameters from a Single Rapid Scan Using the Microsoft Kinect
Many biomechanical analyses rely on the availability of reliable body segment inertia parameter (BSIP) estimates. Current processes to obtain these estimates involve many time consuming manual measurements of the human body, used in conjunction with models or equations. While such methods have become the accepted standard they contain many inherent errors arising from manual measurement and sig...
متن کاملAssessing the Suitability of the Microsoft Kinect for Calculating Person Specific Body Segment Parameters
Many biomechanical and medical analyses rely on the availability of reliable body segment parameter estimates. Current techniques typically take many manual measurements of the human body, in conjunction with geometric models or regression equations. However, such techniques are often criticised. 3D scanning offers many advantages, but current systems are prohibitively complex and costly. The r...
متن کاملComparison of Microsoft Kinect TM and Observational Gait Analysis in the Assessment of Gait Parameters of Apparently Healthy Adults
Objectives: The Microsoft KinectTM is reported to have compelling potentials for gait analysis in medicine; however, there are few data on its comparison with observational gait analysis (OGA). This study compared the Microsoft KinectTM and the OGA in the assessment of gait parameters of apparently healthy adults. Methods: Ninety-seven apparently healthy young male adults participated in this ...
متن کاملComparison of Hospital standards with ISO principles and presentation appropriate model of Hospital standard development
Background: Hospital standards are one of the valuest concepture items in an organization and hospital management. The research purpose was determination of luchs of hospital evaluation current way throght the comparission with ISO quality management standards and suggestion of a model to hospital standard development based on aquired findings. Materials & Methods: This research is a descripti...
متن کاملEngineering Critical Assessments of Marine Pipelines with 3D Surface Cracks Considering Weld Mismatch
Offshore pipelines are usually constructed by the use of girth welds, while welds may naturally contain flaws. Currently, fracture assessment procedures such as BS 7910 are based on the stress-based methods and their responses for situations with large plastic strain is suspicious. DNV-OS-F101 with limited modifications proposes a strain-based procedure for such plastic loads. In this paper 3D ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of sports sciences
دوره 34 11 شماره
صفحات -
تاریخ انتشار 2016