Primary radiation damage of protein crystals by an intense synchrotron X-ray beam.
نویسندگان
چکیده
X-ray radiation damage of a lysozyme single crystal by an intense monochromatic beam from a third-generation radiation source at the Advanced Photon Source has been studied. The results show that primary radiation damage is linearly dependent on the X-ray dose even when the crystal is at cryogenic temperatures. The existence of an upper limit for the primary radiation damage was observed. Above the threshold of approximately 1 x 10(7) Gy, excessive damage of the crystal develops which is interpreted as the onset of secondary and/or tertiary radiation damage. This upper limit of X-ray dose is compared with Henderson's limit [Henderson (1990). Proc. R. Soc. London, B241, 6-8], and its implication for the amount of useful X-ray diffraction data that can be obtained for crystals of a given scattering power is also discussed.
منابع مشابه
Matching X-ray source, optics and detectors to protein crystallography requirements.
A review of the requirements for collecting X-ray diffraction data from protein crystals is given, with an emphasis on the properties of the crystal and its diffraction pattern. The size, unit-cell dimensions and perfection of the crystals can all be related to the required size and divergence of the incident X-ray beam, together with the size and spatial resolution of the detector. The X-ray b...
متن کاملDiffraction before destruction
X-ray free-electron lasers have opened up the possibility of structure determination of protein crystals at room temperature, free of radiation damage. The femtosecond-duration pulses of these sources enable diffraction signals to be collected from samples at doses of 1000 MGy or higher. The sample is vaporized by the intense pulse, but not before the scattering that gives rise to the diffracti...
متن کاملRadiation damage in protein crystals is reduced with a micron-sized X-ray beam.
Radiation damage is a major limitation in crystallography of biological macromolecules, even for cryocooled samples, and is particularly acute in microdiffraction. For the X-ray energies most commonly used for protein crystallography at synchrotron sources, photoelectrons are the predominant source of radiation damage. If the beam size is small relative to the photoelectron path length, then th...
متن کاملRoom-temperature macromolecular serial crystallography using synchrotron radiation
A new approach for collecting data from many hundreds of thousands of microcrystals using X-ray pulses from a free-electron laser has recently been developed. Referred to as serial crystallography, diffraction patterns are recorded at a constant rate as a suspension of protein crystals flows across the path of an X-ray beam. Events that by chance contain single-crystal diffraction patterns are ...
متن کاملSerial femtosecond crystallography: the first five years
Protein crystallography using synchrotron radiation sources has had a tremendous impact on biology, having yielded the structures of thousands of proteins and given detailed insight into their mechanisms. However, the technique is limited by the requirement for macroscopic crystals, which can be difficult to obtain, as well as by the often severe radiation damage caused in diffraction experimen...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of synchrotron radiation
دوره 7 Pt 5 شماره
صفحات -
تاریخ انتشار 2000