OBJECTIVE To evaluate the effect of preoperative intravitreal bevacizumab injection on the incidence of postoperative haemorrhage and visual prognosis, in patients undergoing 25-gauge micro incision vitrectomy surgery (MIVS) for diabetic vitreous haemorrhage. METHODS One hundred and twenty two eyes of 122 patients of diabetic retinopathy of both genders and aged over 18 years, who presented with non-resolving vitreous haemorrhage were enrolled for this study. All patients received an intravitreal injection of 1.25 mg/0.05 mL bevacizumab (Avastin) which was followed one week later by 25-gauge sutureless micro incision vitrectomy surgery. Main outcomes measured were best corrected visual acuity (BCVA) assessed with logMAR and post-operative vitreous haemorrhage. Follow ups were up to six months post-operatively. IBM SPSS 21 was used for data analysis. RESULT A total of 122 patients were included; 78 (63.9%) males and 44 (36.1%) females. Mean age at the time of surgery was 51.4 ± 13.66 years. The mean preoperative BCVA was 1.64 ± 0.427 logMAR which improved to 0.57 ± 0.253 logMAR at 12 months post-operatively (p-value < 0.001). Recurrent vitreous haemorrhage was seen in four patients (3.28%). one1 week before 25-gauge vitrectomy helps to reduce the incidence of early post-vitrectomy haemorrhage in diabetic patients.
منابع مشابه
Faster recovery after 25-gauge microincision vitrectomy surgery than after 20-gauge vitrectomy in patients with proliferative diabetic retinopathy
BACKGROUND AND METHODS We compared surgical procedures and outcomes, including duration of recovery period, in eyes with proliferative diabetic retinopathy that underwent 25-gauge microincision vitrectomy surgery with those that underwent 20-gauge vitrectomy. Seventy-two eyes from 53 patients that underwent 20-gauge vitrectomy in 2006 and 87 eyes from 55 patients that underwent 25-gauge vitrect...
متن کاملDiabetic Vitrectomy is Over and the Retina Remains Attached; What is Next?
At the happy ending of vitreoretinal surgery for proliferative diabetic retinopathy, when all proliferative fibrovascular tissues have been successful ly removed, panret ina l photocoagulation is completed and there is no iatrogenic break, the surgeon may wonder whether to consider any other intervention before closing the case. This question arises in microincision vitrectomies as well as with...
متن کاملVisual outcome of 25-gauge microincision vitrectomy surgery in diabetic vitreous haemorrhage
OBJECTIVE To assess the visual outcome and complications of 25-gauge micro incision vitrectomy surgery (MIVS) in diabetic vitreous haemorrhage. METHODS This Quasi Experimental study was conducted at LRBT, Tertiary eye care hospital Karachi, from February 2012 to January 2013. Sixty eyes of sixty patients with uncontrolled type II diabetes mellitus (DM) were included. There were 43 (71.7%) mal...
متن کاملPerioperative changes of the intraocular pressure during the treatment of epiretinal membrane by using 25- or 27-gauge sutureless vitrectomy without gas tamponade
PURPOSE The purpose of this study was to compare perioperative intraocular pressures (IOPs) in 25- or 27-gauge microincision vitrectomy surgery (MIVS) and to evaluate the stability of postoperative sclerotomy closure. MATERIALS AND METHODS This is a retrospective review of 147 eyes treated for epiretinal membrane by using 25- or 27-gauge MIVS as the initial vitrectomy (25-gauge phacovitrectom...
متن کاملComparison of Surgically-induced Astigmatism after Combined Phacoemulsification and 23-Gauge Vitrectomy: 2.2-mm vs. 2.75-mm Cataract Surgery
PURPOSE The 2.2-mm microincision cataract surgery and small-gauge vitrectomy system is known to result in less surgically-induced astigmatism (SIA) in comparison to conventional surgical methods. We compared the amounts of SIA after combined phacoemulsification and 23-gauge transconjunctival sutureless vitrectomy (23G-TSV) using the 2.2-mm microincision and 2.75-mm standard incision methods. ...