Summary Cardiac Pool Scintigraphy Using the Solid-State Digirad 2020tc ImagerTM —Comparison with the Conventional Anger-Type Gamma Camera Using Moving Cardiac Phantom—

نویسندگان

  • Keiichi CHO
  • Shin-ichiro KUMITA
  • Hidenobu NAKAJO
  • Masahiro TOBA
  • Tetsuji KIJIMA
  • Sunao MIZUMURA
  • Makiko ISHIHARA
  • Takashi OSHINA
  • Minoru SAKURAI
  • Haruyoshi SAITOH
  • Tatsuo KUMAZAKI
چکیده

Movable gamma camera, 2020tc ImagerTM, was light miniaturized using Si photodiode as a semiconductor sensor instead of photomultiplier tubes. To validate performance of this new camera in cardiac pool scintigraphy, multigated equilibrium radionuclide ventriculography using the moving cardiac phantom was performed with 2020tc Imager and a conventional Agner-type gamma camera (PRISM 3000). [Method] Both measured cardiac functional values were compared with the set-up ones for the phantom. Five-, 7.5-, and 10-minute-multigated data were acquired using both cameras under constant contractile condition. Constant 5-minute-multigated data acquisitions using 2020tc Imager were also carried out with varied contractile conditions. [Results] Measured ejection fraction (EF) derived from 2020tc Imager and an Anger-type camera were 68.5±0.6 and 70.3±1.4%, respectively. Both of these values were absolutely close to the set-up EF value of 70%. Both of end-diastolic volume and EF showed excellent correlation between set-up and measured values with the correlation coefficient of 0.97 and 0.99, respectively. [Conclusion] This new movable camera could provide comparative cardiac functional values with an Anger-type camera and it can be useful to evaluate acute cardiac function in a coronary care unit.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of left ventricular function using solid-state gamma camera equipped with a highly-sensitive collimator.

PURPOSE The solid-state gamma camera 2020tc Imager (Digirad, CA) is now commercially available and has been clinically applied. The present study evaluates the feasibility of equilibrium radionuclide ventriculography (ERNV) within a 3 min period using this camera equipped with a highly sensitive collimator. MATERIALS AND METHODS ERNV was performed from the best septal position (left anterior ...

متن کامل

A novel high-sensitivity rapid-acquisition single-photon cardiac imaging camera.

UNLABELLED This study described and validated a new solid-state single-photon gamma-camera and compared it with a conventional-SPECT Anger camera. The compact new camera uses a unique method for localizing gamma-photon information with a bank of 9 solid-state detector columns with tungsten collimators that rotate independently. METHODS Several phantom studies were performed comparing the new ...

متن کامل

Assessment of the solid-state gamma camera to depict axillary sentinel lymph nodes in breast cancer patients.

PURPOSE The solid-state gamma camera is now commercially available offering the advantages of a compact and portable system, currently used mainly in the cardiac region. We evaluate the ability of the solid-state gamma camera to depict axillary sentinel lymph nodes (SLNs) in breast cancer patients. MATERIALS AND METHODS Preoperative SLN lymphoscintigraphy (LSG) was performed in 19 patients wi...

متن کامل

Differential impact of multi-focus fan beam collimation with L-mode and conventional systems on the accuracy of myocardial perfusion imaging: Quantitative evaluation using phantoms

Objective(s): A novel IQ-SPECTTM method has become widely used in clinical studies. The present study compares the quality of myocardial perfusion images (MPI) acquired using the IQ-SPECTTM (IQ-mode),conventional (180° apart: C-mode) and L-mode (90° apart: L-mode) systems. We assessed spatial resolution, image reproducibility and quantifiability using various physical phantoms. Materials and Me...

متن کامل

Cross calibration of 123I-meta-iodobenzylguanidine heart-to-mediastinum ratio with D-SPECT planogram and Anger camera

BACKGROUND Cardiac 123I-meta-iodobenzylguanidine (MIBG) uptake is quantified using the heart-to-mediastinum ratio (HMR) with an Anger camera. The relationship between HMR determined using D-SPECT with a cadmium-zinc-telluride detector and an Anger camera is not fully understood. Therefore, the present study aimed to define this relationship using images derived from a phantom and from patients....

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2002