Volume extreme ultraviolet nano-holographic imaging with numerical optical sectioning.
نویسندگان
چکیده
Three dimensional images were obtained using a single high numerical aperture hologram recorded in a high resolution photoresist with a table top lambda = 46.9 nm laser. Gabor holograms were numerically reconstructed over a range of image planes by sweeping the propagation distance in the numerical reconstruction algorithm, allowing numerical optical sectioning. A robust three dimension image of a test object was obtained with numerical optical sectioning, providing a longitudinal resolution of approximately 2 mum and a lateral resolution of 164 nm.
منابع مشابه
Volume holographic hyperspectral imaging.
A volume hologram has two degenerate Bragg-phase-matching dimensions and provides the capability of volume holographic imaging. We demonstrate two volume holographic imaging architectures and investigate their imaging resolution, aberration, and sensitivity. The first architecture uses the hologram directly as an objective imaging element where strong aberration is observed and confirmed by sim...
متن کاملSpeckle-field digital holographic microscopy.
The use of coherent light in conventional holographic phase microscopy (HPM) poses three major drawbacks: poor spatial resolution, weak depth sectioning, and fixed pattern noise due to unwanted diffraction. Here, we report a technique which can overcome these drawbacks, but maintains the advantage of phase microscopy - high contrast live cell imaging and 3D imaging. A speckle beam of a complex ...
متن کاملNon-axial-scanning multifocal confocal microscopy with volume holography
Wide-field fluorescence microscopy is a commonly used imaging technique by researchers and clinicians. A standard wide-field microscope has no optical sectioning capabilities and this limits its use in imaging thick biological samples. Although standard wide-field fluorescence microscopy with deconvolution techniques can improve image quality [1], it does not provide true optical sectioning, du...
متن کاملHolographic imaging of Zebrafish embryo blood flow with dually oriented illumination beams
An holographic laser Doppler scheme using two illumination beams is proposed to image blood vessel in fish embryo. The coincidence of the reconstructed images made for each illumination orientation leads to an accurate z sectioning. OCIS codes: (090.1995) Digital holography, (110.6150) Speckle imaging, (170.6480) Spectroscopy, speckle. Citation D. Alexandre, G. Lutfalla, and M. Gross, ”Holograp...
متن کاملThree-dimensional holographic fluorescence microscopy.
Most commonly used methods for three-dimensional (3D) fluorescence microscopy make use of sectioning techniques that require that the object be physically scanned in a series of two-dimensional (2D) sections along the z axis. The main drawback in these approaches is the need for these sequential 2D scans. An alternative approach to fluorescence imaging in three dimensions has been developed tha...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Optics express
دوره 15 17 شماره
صفحات -
تاریخ انتشار 2007