Chimera Averaging for Robust SSFP Magnetization Transfer Contrast Imaging (MT-Chimera)

نویسندگان

  • C. Stehning
  • P. Boernert
چکیده

Introduction Recent studies [1] revealed that balanced SSFP shows a pronounced magnetization transfer (MT) contrast, which can be altered via the RF pulse duration and thus allows for quantitative MT imaging [2]. It is thereby assumed that changes in signal intensity are due to the MT effect alone. However, elongated RF pulses entail a prolonged TR, which may introduce signal variations due to the frequency response of balanced SSFP (banding). This obstacle may be tackled by very accurate shimming or frequency offset averaging (OA) [3]. A novel OA approach is investigated in the present study. A linear averaging method based on an SSFP with a linear frequency response [4] is employed, which provides a nearly ideal homogeneous representation irrespectively of off-resonance effects. This allows for MT SSFP imaging over a broad range of TR without stringent requirements to the shimming procedure.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Analytical determination of the chemical exchange saturation transfer (CEST) contrast in molecular magnetic resonance imaging

Magnetic resonance based on molecular imaging allows tracing contrast agents thereby facilitating early diagnosis of diseases in a non-invasive fashion that enhances the soft tissue with high spatial resolution. Recently, the exchange of protons between the contrast agent and water, known as the chemical exchange saturation transfer (CEST) effect, has been measured by applying a suitable pulse ...

متن کامل

Whole heart magnetization-prepared steady-state free precession coronary vein MRI.

PURPOSE To compare two coronary vein imaging techniques using whole-heart balanced steady-state free precession (SSFP) and a targeted double-oblique spoiled gradient-echo (GRE) sequences in combination with magnetization transfer (MT) preparation sequence for tissue contrast improvement. MATERIALS AND METHODS Nine healthy subjects were imaged with the proposed technique. The results are compa...

متن کامل

Investigation of Inter-Slice Magnetization Transfer Effects as a New Method for MTR Imaging of the Human Brain

We present a new method for magnetization transfer (MT) ratio imaging in the brain that requires no separate saturation pulse. Interslice MT effects that are inherent to multi-slice balanced steady-state free precession (bSSFP) imaging were controlled via an interslice delay time to generate MT-weighted (0 s delay) and reference images (5-8 s delay) for MT ratio (MTR) imaging of the brain. The ...

متن کامل

Magnetization Transfer Effects in Wideband SSFP

INTRODUCTION: Wideband SSFP (wbSSFP) is an alternating TR SSFP sequence that provides increased band spacing compared to conventional SSFP [1,2]. Like balanced SSFP (bSSFP), wbSSFP provides high signal-to noise efficiency and T2/T1 weighting. It has recently been shown that the signal intensity of bSSFP is strongly affected by magnetization transfer (MT) effects [3]. There has also been recent ...

متن کامل

Dixon and Chimera: Two methods for fast separation of PFC compounds with small chemical shift difference

Introduction Perfluorocarbon (PFC) emulsions have been widely used for cell tracking studies [1,2] and many other biological applications [3]. In contrast to conventional H contrast agents, F markers provide unambiguous signal in vivo due to the low natural abundance of fluorine in living organisms. Furthermore, fluorine markers can possess a unique spectral signal, a further advantage of F MR....

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009