Objective detection of auditory steady-state responses: comparison of one-sample and q-sample tests.
نویسندگان
چکیده
Auditory steady-state responses (ASSR) are expected to be useful for the objective, frequency-specific assessment of hearing thresholds in small children. To detect ASSR close to the hearing threshold, a powerful statistical test has to be applied. At present, so-called one-sample tests are used. These tests only evaluate the phase, or the phase and amplitude, of the first harmonic, that is, the fundamental frequency. It is shown that higher harmonics with significant amplitudes are also contained in the ASSR spectrum. For this reason, statistical tests that only consider the first harmonic ignore a significant portion of the available information. The use of a q-sample test, which, in addition to the fundamental frequency, also includes higher harmonics in the detection leads to a better detection performance. The evaluation of test performance uses both detection rate and detection time.
منابع مشابه
Effect of Mild Cognitive Impairment and Alzheimer Disease on Auditory Steady-State Responses
Introduction: Mild Cognitive Impairment (MCI), a disorder of the elderly people, is difficult to diagnose and often progresses to Alzheimer Disease (AD). Temporal region is one of the initial areas, which gets impaired in the early stage of AD. Therefore, auditory cortical evoked potential could be a valuable neuromarker for detecting MCI and AD. Methods: In this study, the thresholds of...
متن کاملObjective detection of auditory steady-state evoked potentials based on mutual information.
OBJECTIVE Recently, we developed a metric to objectively detect human auditory evoked potentials based on the mutual information (MI) between neural responses and stimulus spectrograms. Here, the MI algorithm is evaluated further for validity in testing the auditory steady-state response (ASSR), a sustained potential used in objective audiometry. DESIGN MI was computed between spectrograms of...
متن کاملComparing statistics for objective detection of transient and steady-state evoked responses in newborns.
OBJECTIVE Receiver operating characteristic (ROC) methodology was used to compare the performance of different statistics in the automatic detection of multiple auditory steady-state responses (MSSR) and click auditory brainstem responses (cABR). STUDY SAMPLE Thirty-five healthy newborns tested within the first two weeks of birth. DESIGN In each case cABR and MSSR (0.5 and 2 kHz) were recor...
متن کاملNew efficient stimuli for evoking frequency-specific auditory steady-state responses.
ASSR is a promising tool for the objective frequency-specific assessment of hearing thresholds in children. The stimulus generally used for ASSR recording (single amplitude-modulated carrier) only activates a small area on the basilar membrane. Therefore, the response amplitude is low. A stimulus with a broader frequency spectrum can be composed by adding several cosines whose frequency interva...
متن کاملTesting time comparison between two procedures with new technologies of Automated Auditory Brainstem
Purpose: To compare the testing time of two Automated Auditory Brainstem Response (AABR) procedures using different repetition rates and detection modes. Methods: A hearing screening using AABR was performed in 30 newborns with mean age of 21 days. Each newborn was submitted to two hearing screening procedures using different AABR equipments (Procedure 1 and Procedure 2). Procedure 1 used a rep...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of the American Academy of Audiology
دوره 17 2 شماره
صفحات -
تاریخ انتشار 2006