Investigation of oxygen saturation derived from cardiac pulsations measured on the adult head using NIR spectroscopy.
نویسندگان
چکیده
Cardiac related pulsatile signals can be detected in different parts of the human body, including the finger, ear lobe and forehead [1] by using near infrared (NIR) monitoring. These pulsatile signals are due to attenuation of light by the increase of arterial blood volume during systole in the cardiac cycle. Pulse oximetry exploits these pulsatile signals to calculate oxygen saturation (SpO2) [2]. There are two types of pulse oximetry: (1) the transmission type where the light source and detector are facing each other across the measurement site (e.g. ear lobe or finger), and (2) the reflectance type where both the light source and detector are in the same plane (e.g. forehead or forearm) [1] with the source detector spacing typically less than 1 cm. With more sensitive optical instruments, it has been shown that these pulsatile signals can be measured on the forehead at a greater spacing using either a CCD spectrometer [3] or a phase resolved system [4]. Both of these two methods can be considered as operating in reflectance mode with large source detector spacings of 3 or 3.5 cm. These pulsatile signals were also thought to be mainly caused by the change in arterial blood volume. However, at source detector spacing larger than ~2 cm, NIR light can penetrate through the skull into the brain and the measured pulsatile signals are likely partly to include components caused by brain movement [5] as well as arterial blood pulsations in the scalp and the brain. The objective of this paper is to compare three algorithms used to calculate oxygen saturation from the head pulsatile signals, (signified by SpO2 to distinguish it from SpO2 measured at other sites) with large source detector spacing. Two of the algorithms implicitly allow the possibility of venous blood contributing to SpO2. We will show the SpO2 calculated by three algorithms in 8 adult subjects during normoxia and hypoxia. Examples of phase differences between the oxy and deoxy-haemoglobin (∆HbO2 and
منابع مشابه
Correlation of intraoperative renal near infrared spectroscopy with the development of acute kidney injury in adult patients undergoing cardiac surgery using cardiopulmonary bypass
Introduction: The present study aimed to correlate renal oximetry near-infrared spectroscopy (NIRS) values with conventional non-invasive biomarkers for the early detection of acute kidney injury (AKI) in adult patients undergoing cardiac surgery using cardiopulmonary bypass (CPB). Accordingly, renal NIRS can be employed as a trending device for the prevention of AKI developmen...
متن کاملCerebral tissue oxygen saturation calculated using low frequency haemoglobin oscillations measured by near infrared spectroscopy in adult ventilated patients.
Oxy- (HbO2) and deoxy- (HHb) haemoglobin signals measured by near infrared (NIR) spectroscopy over the human frontal lobes frequently contain respiratory and low frequency oscillations (LFOs). It has been suggested previously that venous oxygen saturation (SvO2) can be calculated from these respiratory oscillations. In this paper, we investigated the use of a Fourier transform based algorithm t...
متن کاملMagnetic-resonance-imaging-coupled broadband near-infrared tomography system for small animal brain studies.
A novel magnetic-resonance-coupled broadband near-infrared (NIR) tomography system for small animal brain studies is described. Several features of the image formation approach are new in NIR tomography and represent major advances in the path to recovering high-resolution hemoglobin and oxygen saturation images of tissue. The NIR data were broadband and continuous wave and were used along with...
متن کاملNear-infrared spectroscopy technique to evaluate the effects of red blood cell transfusion on tissue oxygenation
INTRODUCTION The aim of this study was to evaluate the effects of red blood cell (RBC) transfusions on muscle tissue oxygenation, oxygen metabolism and microvascular reactivity in critically ill patients using near-infrared spectroscopy (NIRS) technology. METHODS This prospective, observational study included 44 consecutive patients hospitalized in the 31-bed, medical-surgical intensive care ...
متن کاملQualitative near-infrared vascular imaging system with tuned aperture computed tomography.
We developed a novel system for imaging and qualitatively analyzing the surface vessels using near-infrared (NIR) radiation using tuned aperture computed tomography (TACT(®)). The system consisted of a NIR-sensitive CCD camera surrounded by sixty light emitting diodes (with wavelengths alternating between 700 or 810 nm). This system produced thin NIR tomograms, under 0.5 mm in slice thickness. ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Advances in experimental medicine and biology
دوره 578 شماره
صفحات -
تاریخ انتشار 2006