Percutaneous bilateral pulmonary artery banding using a re-expandable covered stent: preliminary animal study

نویسندگان

  • Yayoi Nakahata
  • Hideshi Tomita
  • Sumito Kimura
  • Hisashi Ando
  • Takashi Honda
  • Manabu Takanashi
  • Yoshihito Ogihara
  • Masahiro Ishii
چکیده

Backgrounds: Bilateral pulmonary artery banding (bPAB) followed by ductal stenting has been reported as a stage 1 palliation of hypoplastic left heart syndrome (HLHS). However, hybrid strategy, which includes median sternotomy for bPAB, has been a common approach. In this preliminary experiment, we investigated the feasibility of a transcatheter bPAB followed by debanding using a reexpandable covered stent for comprehensive transcathter stage 1 palliation. Methods: Polyurethane was coated on Palmaz medium (Palmaz) or Express Vascular LD (large diameter) (Express) stents using the dipping method. The stent was mounted on a balloon, tied at the midpoint with a silk thread so as to implant the stent in the bilateral pulmonary arteries in a dumbbell shape, which consequently created bPAB. Under general anesthesia, we intended to create bPAB in 5 piglets whose median body weight was 10.1 kg. Once bPAB was created successfully, we performed debanding with balloon dilatation. Results: Eight stents (Palmaz and Express, 4 each) were implanted in 4 piglets, but one piglet died while manipulating a long sheath in the right ventricular outflow tract associated with fetal arrhythmia. Meanwhile, debanding was attempted of 4 stents (Palmaz and Express, 2 each) in 3 piglets because another piglet died suddenly of right ventricular failure following bPAB. All of the Palmaz stents were successfully implanted in a dumbbell shape, while only 2 Express stents could be implanted in the dumbbell shape. The Palmaz stents were debanded successfully, while only one Express stent could be redilated sufficiently because cells of the mid-portion overlapped each other. Conclusions: Transcather PAB could be created using a covered stent implanted in a dumbbell shape. The material and design of the stents were key issues not only for the creation of PAB but also for debanding. Further innovation of stents will be necessary for clinical utilization of this technique as a comprehensive transcatheter stage 1 palliation of HLHS.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Customized covered stent graft for percutaneous closure of Fontan baffle leak.

We report the innovation of both a partly-covered and completely-covered, variable-diameter, balloon-expandable stent that was custom-designed by NuMed, Inc for percutaneous closure of a baffle leak after total caval pulmonary connection (TCPC). A 50-year-old patient, born with tricuspid atresia, who had undergone TCPC, developed severe persistent cyanosis due to a right-to-left shunt through a...

متن کامل

A novel adjustable pulmonary artery banding system for hypoplastic left heart syndrome.

OBJECTIVE Hypoplastic left heart syndrome remains a challenge for worldwide surgeons. Initial palliation employing bilateral pulmonary artery banding along with ductal stent implantation and atrial septostomy has been proposed as an alternative approach. However, the surgically placed bands are fixed and may become inadequate after sternum closure or with somatic growth of the patient. We descr...

متن کامل

CONGENITAL HEART DISEASE Stenting of the ductus arteriosus and banding of the pulmonary arteries: basis for various surgical strategies in newborns with multiple left heart obstructive lesions

Objective: To present an institutional experience with stent placement in the arterial duct combined with bilateral banding of the pulmonary artery branches as a basis for various surgical strategies in newborns with hypoplastic left heart obstructive lesions. Design: Observational study. Setting: Paediatric heart centre in a university hospital. Patients: 20 newborns with various forms of left...

متن کامل

Acquired Infrarenal Abdominal Aortic Coarctation: Treatment with Percutaneous Self Expandable Stent

Abdominal aortic coarctation is an extremely rare vascular pathology. Its etiology can be congenital or acquired. Here we present a case of acquired infrarenal abdominal coarctation in a 66-year-old woman who complained of low back and legs pain. She had no signs of resting lower limb ischemia, with diminished distal pulses and normal blood pressure in upper and lower extremities. Magnetic reso...

متن کامل

Stenting of the ductus arteriosus and banding of the pulmonary arteries: basis for various surgical strategies in newborns with multiple left heart obstructive lesions.

OBJECTIVE To present an institutional experience with stent placement in the arterial duct combined with bilateral banding of the pulmonary artery branches as a basis for various surgical strategies in newborns with hypoplastic left heart obstructive lesions. DESIGN Observational study. SETTING Paediatric heart centre in a university hospital. PATIENTS 20 newborns with various forms of le...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011