Argon I Lines Produced in a Hollow Cathode Source, 332 nm to 5865 nm

نویسندگان

  • W. Whaling
  • W. H. C. Anderson
  • M. T. Carle
  • J. W. Brault
  • H. A. Zarem
چکیده

We report precision measurements by Fourier transform spectroscopy of the vacuum wavenumber, line width, and relative signal strength of 928 lines in the Ar I spectrum. Wavelength in air and classification of the transition are supplied for each line. A comparison of our results with other precision measurements illustrates the sensitivity of Ar I wavelengths to conditions in the light source.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comment on “Argon I Lines Produced in a Hollow Cathode Source, 332 nm to 5865 nm”

Recent observations at the National Institute of Standards and Technology indicate that the Ar I wavenumbers reported by Whaling et al. [J. Res. Natl. Inst. Stand. Technol. 107, 149 (2002)] are systematically too large. To investigate the source of this problem, selected lines of Ar I and Ar II were remeasured in the same spectra used by Whaling et al. The measurements show that the Ar I wavenu...

متن کامل

High current hollow cathode as a radiometric transfer standard source for the extreme vacuum ultraviolet.

A high current hollow cathode source has been developed as a radiometric source standard for the extreme VUV. The source is operated at a constant current of 2 A with an aluminum cathode and helium or argon as buffer gas at pressures of ~1 hPa. The radiance of spectral lines in the wavelength range from 13 to 60 nm has been determined by comparison to the calculable spectral radiant power of th...

متن کامل

A high - current hollow cathode as a source of intense line radiation in the vuv

The vuv line emission of a high-current DC hollow cathode was investigated in the wavelength region 10 nm to 100 nm. Spectra of quadruply ionised atoms could be observed. The radiance in the AI IV lines at 13 nm and 16 nm and in the He I1 Lyman-series was determined by a comparison with the spectral concentration of radiant intensity of the synchrotron radiation emitted by the electron storage ...

متن کامل

Absolute intensity calibration of the Wendelstein 7-X high efficiency extreme ultraviolet overview spectrometer system.

The new high effiency extreme ultraviolet overview spectrometer (HEXOS) system for the stellarator Wendelstein 7-X is now mounted for testing and adjustment at the tokamak experiment for technology oriented research (TEXTOR). One part of the testing phase was the intensity calibration of the two double spectrometers which in total cover a spectral range from 2.5 to 160.0 nm with overlap. This w...

متن کامل

Generation of high energy, 30 fs pulses at 527 nm by hollow-fiber compression technique.

The compression of 300-fs-long, chirp-free laser pulses at 527 nm down to 30 fs is reported. The laser pulses, originated from a frequency-doubled, mode-locked Nd:glass laser, were compressed by a 0.7-m-long, 150-microm-bore-diameter, argon-filled hollow fiber, and a pair of SF10 prisms with a final energy of 160 microJ. These are the shortest, high energy pulses ever produced by direct pulse c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 107  شماره 

صفحات  -

تاریخ انتشار 2002