Selective and simultaneous determination of phosphate and silicate ions in leaching process waters for ceramics glaze raw materials of narutal origin by ion-exclusion chromatography coupled with UV-detection after postcolumn derivatization.

نویسندگان

  • Mikaru Ikedo
  • Masanobu Mori
  • Kazumasa Kurachi
  • Wenzhi Hu
  • Kazuhiko Tanaka
چکیده

The selective and simultaneous ion-exclusion chromatography (IEC) with UV-detection on a weakly acidic cation-exchange resin column in the H+ -form (TSKgel Super IC-A/C) was developed and applied for the simultaneous determination of phosphate and silicate ions as the water quality parameters required for optimizing the water-leaching process for ceramics glaze raw materials of natural origin including feldspar, woods-ash, and straw-ash. Phosphate and silicate ions in these water-leaching process water samples were separated selectively from the coexisting anions such as sulfate, chloride, nitrate and carbonate ions, based on the ion-exclusion separation mechanism. They were detected selectively and simultaneously by a postcolumn derivatization with molybdenum-yellow using the UV-detector. Under the optimized separation and detection conditions (eluent, 0-1 mM sulfuric acid; reactant, 10 mM sodium molybdate-25 mM sulfuric acid; detector, UV at 370 nm; temperature, 45 degrees C), the linearity of calibration was in the range 0.1 - 10 ppm for both phosphate and silicate ions, and the detection limits at S/N = 3 were 2.58 ppb for silicate ions and 4.75 ppb for phosphate ions. The effectiveness of this method was demonstrated in practical applications to the water-leaching process for some ceramics glaze raw materials.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simultaneous spectrophotometric determination of orthophosphate and silicate ions in river water using ion-exclusion chromatography with an ascorbate solution as both eluent and reducing agent, followed by postcolumn derivatization with molybdate.

Ion-exclusion chromatography was examined for the simultaneous spectrophotometric determinations of orthophosphate and silicate ions in river water using an ascorbate solution as both an eluent and a reducing agent, followed by postcolumn derivatization using molybdate. The detector responses for both ions increased with increased ascorbic acid concentration in the eluent, but peak tailing was ...

متن کامل

Simultaneous spectrophotometric determination of phosphate and silicate ions in river water by using ion-exclusion chromatographic separation and post-column derivatization.

The simultaneous spectrophotometric determination of phosphate and silicate ions in river water was examined by using ion-exclusion chromatography and post-column derivatization. Phosphate and silicate ions were separated by the ion-exclusion column packed with a polymethacrylate-based weakly acidic cation-exchange resin in the H(+)-form (TSKgel Super IC-A/C) by using ultra pure water as an elu...

متن کامل

Determination of thiamine and its esters in beers and raw materials used for their manufacture by liquid chromatography with postcolumn derivatization.

Thiamine and its mono- and pyrophosphate esters were determined in beer and the raw materials used for its manufacture (brewer's yeast, malt, raw grain, and hops) after separation using reversed-phase liquid chromatography. The method used fluorescence detection and a new amide-based stationary phase, which avoids the need to form ion pairs, leading to narrower peaks and a simpler mobile phase....

متن کامل

High Performance Liquid Chromatography Coupled with Pre-column Derivatization for Determination of Oxidized Glutathione Level in Rats Exposed to Paraquat

Glutathione (GSH) is one of the most important antioxidants that plays an essential role in detoxification of reactive oxygen species (ROS) which oxidizes to glutathione disulfide (GSSG). Paraquat (PQ), awidely used herbicide, causes pulmonary injury with the productionof ROS. Excessive ROS accumulation as a consequence of PQ exposure are frequently targeted by GSH thereby oxidative stress lead...

متن کامل

High Performance Liquid Chromatography Coupled with Pre-column Derivatization for Determination of Oxidized Glutathione Level in Rats Exposed to Paraquat

Glutathione (GSH) is one of the most important antioxidants that plays an essential role in detoxification of reactive oxygen species (ROS) which oxidizes to glutathione disulfide (GSSG). Paraquat (PQ), awidely used herbicide, causes pulmonary injury with the productionof ROS. Excessive ROS accumulation as a consequence of PQ exposure are frequently targeted by GSH thereby oxidative stress lead...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical sciences : the international journal of the Japan Society for Analytical Chemistry

دوره 22 1  شماره 

صفحات  -

تاریخ انتشار 2006