Comparison of circumferential pulmonary vein anatomy mapping guided by 3D mapping versus a mesh mapping catheter

نویسندگان

  • Yi-Wen Yan
  • Gang Chen
  • Feng Zhang
  • Song-Wen Chen
  • Wei-Dong Meng
  • Shao-Wen Liu
چکیده

OBJECTIVE Catheter-based pulmonary vein isolation (PVI) is an established therapy for paroxysmal atrial fibrillation. The high-density mesh mapper (HDMM) guides circumferential PV-atrium isolation without the 3D electroanatomic mapping. This study aims to compare circumferential pulmonary vein (CPV) anatomy mapping between guiding by a 3D mapping system and the HDMM. METHODS Forty-four consecutive patients with paroxysmal atrial fibrillation were scheduled for a first procedure for PVI. A CPV ostial anatomy map guided by HDMM was set up in the CARTO system while the operator was blinded to the CARTO screen. Then CARTO-guided ipsilateral PV maps were obtained and PVI was performed. This established another set of CPV ostial anatomy maps. The differences between the two mapping images were compared and analyzed. RESULTS All 176 PVs in 44 patients could be mapped by both HDMM and CARTO. About 44.9% of the PV ostial anatomies were generally similar between the two different map images. The average point-to-point straight distance between the HDMM-guided map and the CARTO-guided map was 6.2 ± 1.4 mm. The area of the circumferential right PV (CRPV) in the HDMM map was larger than that in the CARTO map (P = 0.013). After a mean follow-up of 18.3 ± 4.3 months (6-24 months), 72.7% of patients (32/44) were free of atrial arrhythmia without anti-arrhythmic drugs (AADs). CONCLUSION Compared to the CARTO-guided CPV anatomy image, a highly similar figure could be achieved by mapping guided by the HDMM. (Clinical trial.gov number, ChiCTR-TNRC-11001390.).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intracardiac ECHO Integration with Three Dimensional Mapping: Role in AF Ablation.

Background: Catheter ablation of atrial fibrillation (AF) is typically guided by 3D mapping. This involves point-by-point reconstruction of the 3D virtual anatomy and may be time consuming and require substantial fluoroscopy exposure. Intracardiac echocardiography (ICE) affords real time imaging of the cardiac structures during mapping and ablation. Methods: Between February and May 2007, 15 pa...

متن کامل

Pulmonary Vein Isolation with a Multielectrode Basket Catheter

Pulmonary vein (PV) isolation (PVI) techniques have evolved as a curative treatment of atrial fibrillation (AF) since PVI guided by circumferential mapping with a circular catheter was initially proposed. A multielectrode basket catheter (MBC) is also useful for PVI because of some advantages; (1) an MBC provides some information about the PV anatomy on the fluoroscopic image, (2) an MBC can ut...

متن کامل

Percutaneous transapical access for pulmonary vein mapping and ablation in a porcine model with a new high-density electroanatomical mapping system.

INTRODUCTION The porcine model is generally accepted for the development and testing of new forms oftherapy including ablation of atrial fibrillation (AF). However, the challenging left atrial (LA) and pulmonary vein (PV) anatomy enables only limited percutaneous catheter-based PV access. RESULTS Here we present I) an alternative percutaneous transapical access, which enables easy and safe re...

متن کامل

Combined Cardiac and Respiratory Motion Compensation for Atrial Fibrillation Ablation Procedures

Catheter ablation of atrial fibrillation has become an accepted treatment option if a patient no longer responds to or tolerates drug therapy. A main goal is the electrical isolation of the pulmonary veins attached to the left atrium. Catheter ablation may be performed under fluoroscopic image guidance. Due to the rather low soft-tissue contrast of X-ray imaging, the heart is not visible in the...

متن کامل

Three-dimensional ultrasound for image-guided mapping and intervention: methods, quantitative validation, and clinical feasibility of a novel multimodality image mapping system.

BACKGROUND Multiple factors create discrepancies between electroanatomic maps and merged, preacquired computed tomographic images used in guiding atrial fibrillation ablation. Therefore, a Carto-based 3D ultrasound image system (Biosense Webster Inc) was validated in an animal model and tested in 15 atrial fibrillation patients. METHODS AND RESULTS Twelve dogs underwent evaluation using a new...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 1  شماره 

صفحات  -

تاریخ انتشار 2015