Electrophoretic behavior of serum amylase.

نویسندگان

  • R L McGEACHIN
  • J P LEWIS
چکیده

There have been several indications (1, 2) that the amylase found in serum is derived from sources other than the pancreas or salivary glands. For this reason we wished to determine whether any indication of fractionation of serum amylase could be obtained by paper electrophoresis. Although several accounts of the fractionation of amylase in serum are found in the literature, some involving precipitation and some involving electrophoresis, these data sometimes do not agree with one another and in other cases are rather limited. Cattaneo and Bassani (3), using acetone fractionation at low temperature, found that amylase in human serum always accompanied the albumin fraction, in horse serum, the globulin fraction. Baker and Pellegrino (4) using paper electrophoresis with human serum found amylase principally in the slow portion of the y-globulin with only small amounts in the more mobile fractions. Data for four subjects were presented. In paper electrophoresis with mouse serum, Delcourt and Delcourt (5) found amylase principally (about 75 per cent) in the pland &globulin fractions. Kunkel and Eberhard,’ in a single run using powdered plastic Geon in zone electrophoresis with human serum, found amylase mainly in the albumin fraction and a small amount with the al-globulin but none with the y-globulin fraction. In this study, serum fractions obtained by paper electrophoresis were analyzed by a micromodification of the amylase method of Van Loon et al. (6). Experiments in which serum was mixed with human saliva or pancreatic juice suggest the presence of some serum amylase different from salivary or pancreatic amylase.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Electrophoretic pattern of amylase isoenzymes in serum and urine of normal persons.

We separated and measured amylase isoenzymes in the serum and urine of 3036 normal persons by electrophoresis on a thin layer of polyacrylamide gel. We wished to establish the normal pattern of these isoenzymes and to evaluate the usefulness of this method of electrophoresis in clinical diagnosis. Results for patients with hyper- or hypofunctioning pancreas and salivary glands suggested that es...

متن کامل

Rapid quantitative, specific measurement of pancreatic amylase in serum with use of a monoclonal antibody.

In this rapid quantitative assay for pancreatic alpha-amylase (EC 3.2.1.1) in serum, we precipitate salivary amylases by 10-min incubation with monoclonal anti-salivary amylase antibody immobilized on particles of polyvinylidene fluoride. We then centrifuge the serum mixture and measure the pancreatic amylase activity remaining in the supernate by a kinetic method. The assay requires 50 microL ...

متن کامل

Serum lipase activity is increased in disease states other than acute pancreatitis: amylase revisited.

For more than 50 years, total serum amylase activity has been the biochemical test most commonly used to confirm the clinical diagnosis of acute pancreatitis. Serum amylase activity has been hoisted onto this pedestal by default, because until recently it has been the only reproducible and rapid diagnostic assay available in clinically emergent settings. As a result of our longstanding dependen...

متن کامل

Differential serum amylase determination by use of an inhibitor, and design of a routine procedure.

We describe a new method for measuring pancreatic and salivary-type amylases in serum that requires no electrophoresis or chromatography. An inhibitor protein (from wheat) with a 100-fold greater specificity for human salivary than for human pancreatic amylase was used to analyze mixtures of the two enzymes. The concentration of pancreatic and salivary amyalase was determined in 141 normal sera...

متن کامل

Agarose electrophoresis and inhibitor tests for isoamylase determination can give complementary clinical information.

We report the presence of an extremely high proportion of "aged" amylase in the serum and cyst fluid of a patient with a pancreatic pseudocyst. A salivary amylase inhibitor test helped us to differentiate these "aged" pancreatic amylases from salivary fractions having a similar electrophoretic mobility.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of biological chemistry

دوره 234 4  شماره 

صفحات  -

تاریخ انتشار 1959