No adverse effects of submelt-annealed highly crosslinked polyethylene in cemented cups
نویسندگان
چکیده
BACKGROUND AND PURPOSE Highly crosslinked polyethylene (PE) is in standard use worldwide. Differences in the crosslinking procedure may affect the clinical performance. Experimenatal data from retrieved cups have shown free radicals and excessive wear of annealed highly crosslinked PE. We have previously reported low wear and good clinical performance after 6 years with this implant, and now report on the 10-year results. PATIENTS AND METHODS In 8 patients, we measured wear of annealed highly crosslinked PE prospectively with radiostereometry after 10 years. Activity was assessed by UCLA activity score and a specifically designed activity score. Conventional radiographs were evaluated for osteolysis and clinical outcome by the Harris hip score (HHS). RESULTS The mean (95% CI) proximal head penetration for highly crosslinked PE after 10 years was 0.07 (-0.015 to 0.153) mm, and the 3D wear was 0.2 (0.026 to 0.36) mm. Without creep, proximal head penetration was 0.02 (-0.026 to 0.066) mm and for 3D penetration was 0.016 (-0.47 to 0.08) mm. This represents an annual proximal wear of less than 2 µm. All cups were clinically and radiographically stable but showed a tendency of increased rotation after 5 years. INTERPRETATION Wear for annealed highly crosslinked PE is extremely low up to 10 years. Free radicals do not affect mechanical performance or lead to clinically adverse effects. Creep stops after the first 6 months after implantation. Highly crosslinked PE is a true competitor of hard-on-hard bearings.
منابع مشابه
Notch Effects Under Physiologically-Relevant Conditions of Conventional and Highly Crosslinked UHMWPEs
Introduction: Ultra high molecular weight polyethylene (UHMWPE) components used in total joint replacements have rims and fillets that act as design stress risers; thus, it is of interest to determine the behavior UHMWPE under multiaxial loading conditions. Currently, there are a number of conventional and crosslinked UHMWPE formulations in clinical use in total hip and total knee replacement c...
متن کاملWear, bone density, functional outcome and survival in vitamin E-incorporated polyethylene cups in reversed hybrid total hip arthroplasty: design of a randomized controlled trial
BACKGROUND Aseptic loosening of total hip arthroplasties is generally caused by periprosthetic bone resorption due to tissue reactions on polyethylene wear particles. In vitro testing of polyethylene cups incorporated with vitamin E shows increased wear resistance. The objective of this study is to compare vitamin E-stabilized highly cross-linked polyethylene with conventional cross-linked poly...
متن کاملTotal hip arthroplasty in patients less than 40 years old with avascular necrosis of the femoral head. A 5 to 19-year follow-up study.
We evaluated 34 total hip arthroplasties (THA) for avascular necrosis of the femoral head in 26 patients who were younger than 40 years at the time of the index operation. The average age at the time of THA was 283 (17-38) years. The mean follow-up was 10.9 (5-19) years. We used 6 cemented and 28 cementless acetabular components and a cemented polished tapered stem in all hips. The mean Charnle...
متن کاملCemented Polyethylene Cups in Patients Younger Than 40 Years
UNLABELLED Although uncemented cup implants frequently are used in young patients, we believe long-term survival rates of cups in these patients are somewhat disappointing, and therefore we have continued to use cemented cups in primary THA, even in young patients. However, in cases of acetabular bone stock defects, we also use bone impaction grafting. We prospectively followed 130 patients wit...
متن کاملPolyethylene wear in cemented metal-backed acetabular cups.
We examined radiographic polyethylene wear in 233 cemented total hip arthroplasties (201 patients) with either a metal-backed or a non-metal-backed acetabular cup. All patients had identical cemented one-piece titanium femoral stems with a femoral head diameter of 28 mm. The mean linear wear rate was 0.11 mm/yr in metal-backed sockets and 0.08 mm/yr in non-metal-backed sockets (p = 0.0002). The...