Real-time monitoring of stain formation and removal on calcium hydroxyapatite surfaces using quartz crystal sensor technology.

نویسندگان

  • J Langford
  • K D Pavey
  • C J Olliff
  • P J Cragg
  • G W Hanlon
  • F Paul
  • G D Rees
چکیده

Stain formation, stain inhibition and stain removal may be monitored in real-time using a novel method employing a quartz crystal resonance sensor (QCR), based upon quartz crystal microbalance (QCM) technologies. Crystalline hydroxyapatite (HA) surfaces were prepared on phosphate-terminated, polymer-modified gold surfaces of quartz crystal transducers. The resulting sensors were placed in a specially constructed flow cell, and the interaction of adsorbates from the tea stain solution monitored as a function of time. The ability of sodium tripolyphosphate (STP) to remove extrinsic stain and also to inhibit its formation was examined. The adsorption of material from the staining solution passed over the sensor was clearly observable, and once bound, the crystal based real-time data suggest that tea adsorbates were not removed in the absence of an active under conditions of continuous flow. STP was shown to rapidly remove existing stain, and exhibited a clear inhibitory action on stain formation irrespective of whether the HA had been previously exposed to tea chromogens. The continuous data generated by the QCR technique were in good agreement with the results obtained using a discontinuous spectrophotometric method. The presently described quartz crystal model for extrinsic dental stain should provide a valuable tool to aid understanding of the interactions of staining agents with a crystalline HA surface as a model tooth surface, and to evaluate the efficacy and mode of action of STP and putative stain removal agents.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reusable hydroxyapatite nanocrystal sensors for protein adsorption.

The repeatability of the adsorption and removal of fibrinogen and fetal bovine serum on hydroxyapatite (HAp) nanocrystal sensors was investigated by Fourier transform infrared (FTIR) spectroscopy and quartz crystal microbalance with dissipation (QCM-D) monitoring technique. The HAp nanocrystals were coated on a gold-coated quartz sensor by electrophoretic deposition. Proteins adsorbed on the HA...

متن کامل

A rapid, non-destructive method for the determination of Staphylococcus epidermidis adhesion to surfaces using quartz crystal resonant sensor technology.

AIMS To investigate the use of quartz crystal resonant sensor (QCRS) technology to determine the adhesion of Staphylococcus epidermidis to fibronectin-coated surfaces. METHODS AND RESULTS QCRS sensors (14 MHz) with 4 mm gold electrodes were coated with fibronectin and exposed for 15 min to suspensions of Staph. epidermidis ranging in concentration from 1 x 10(2) to 1 x 10(6) cfu ml(-1). Chang...

متن کامل

Effect of Surfactant in Formation of Hydroxyapatite Nano-Rods under Hydrothermal Conditions

      Hydroxyapatite (HA) nano-rods with uniform morphology and controllable size have been successfully synthesized in the presence of cationic and non-ionic surfactants by a hydrothermal method. (NH4) 2HPO4 and Ca(NO 3)2.4H2O were used as the phosphorus and calcium sources, respectively. The composition of synthesized powders w...

متن کامل

Probing the Interaction between Nanoparticles and Lipid Membranes by Quartz Crystal Microbalance with Dissipation Monitoring

There is increasing interest in using quartz crystal microbalance with dissipation monitoring (QCM-D) to investigate the interaction of nanoparticles (NPs) with model surfaces. The high sensitivity, ease of use and the ability to monitor interactions in real-time has made it a popular technique for colloid chemists, biologists, bioengineers, and biophysicists. QCM-D has been recently used to pr...

متن کامل

Real-Time Monitoring of Fibrinogen Cross-Linking on Model Biomaterial Surfaces with Quartz Crystal Microbalance

A quartz crystal microbalance was used for real-time monitoring of fibrinogen cross-linking on three model biomaterial surfaces. Fibrinogen adsorbs slowly and forms a less rigid multi-layer on hydrophobic surfaces, while it adsorbs quickly, forming a single mono-layer on hydrophilic surfaces. The extent of fibrinogen cross-linking is greater on hydrophobic surfaces. Fibrinogen cross-linking can...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Analyst

دوره 127 3  شماره 

صفحات  -

تاریخ انتشار 2002