Treatment of Dropped Nucleus with a 27-Gauge Twin Duty Cycle Vitreous Cutter

نویسندگان

  • Akira Watanabe
  • Akane Tsuzuki
  • Kota Arai
  • Tamaki Gekka
  • Hiroshi Tsuneoka
چکیده

We report herein a method for the treatment of dropped nucleus during cataract surgery with a 27-gauge twin duty cycle (TDC) vitreous cutter. When a TDC vitreous cutter is used, suction flow volume is maintained even when the cutter is driven at a high speed. This enables an Emery-Little grade 3 nucleus that had been difficult to treat with a conventional 27-gauge cutter to be successfully excised using only a vitreous cutter, with no intra- or postoperative complications. A dropped lens during cataract surgery of up to moderate hardness can be removed using a TDC cutter alone with a 27-gauge cutter system.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Getting Familiar With EVA

USEFUL FEATURES Twin Duty Cycle EVA’s twin duty cycle (TDC) technology (Figure) provides a high cut rate of 16 000 cpm with a constant open duty cycle of 92%. It significantly reduces the time to complete a core vitrectomy when compared with the Associate (DORC) and other non-TDC machines. A complete core vitrectomy with the 23-gauge system and TDC technology takes an average of 3 to 4 minutes....

متن کامل

Performance of a Modified Vitrectomy Probe in Small - gauge Vitrectomy

S mall-gauge sutureless pars plana vitrectomy reduces postoperative inflammation at the sclerotomy sites in comparison with conventional 20-gauge sutured pars plana vitrectomy, thus decreasing patient discomfort postoperatively and hastening recovery.1-5 Despite the clinical advantages of smaller diameter vitrectomy systems, they pose significant challenges in vitreous removal as they decrease ...

متن کامل

Fluidics in a dual pneumatic ultra high-speed vitreous cutter system.

BACKGROUND Dual pneumatic systems use two separate air line tubes to open and close the cutter and can achieve high cut rates. The purpose of this study is to evaluate the influence of gauge size, cut rate and aspiration on the flow rate performance of ultra high-speed cutters operated with a commercially available dual pneumatic vitrectomy system. METHODS Analysis of a high-speed video was u...

متن کامل

Introducing new vitreous cutter blade shapes: a fluid dynamics study.

PURPOSE To assess the efficacy of novel vitreous cutter blades compared with the regular guillotine by means of particle image velocimetry. Tested blades included a regular blade (RB) and newer designs where a circular (hole blade [HB]) or a slit aperture (slit blade [SB]) had been opened proximal to the cutting edge. METHODS Twenty-three-gauge probes were immersed in BSS or egg albumen, and ...

متن کامل

Porcine Vitreous Flow Behavior During High-Speed Vitrectomy up to 7500 Cuts per Minute

PURPOSE To evaluate the impact of high-speed cut rates (up to 7500 cuts per minute [cpm]) on vitreous flow through various gauge probes. METHODS An open-sky vitrectomy technique was performed on porcine eyes using the CONSTELLATION Vision System with three different gauges of dual-pneumatic probes (27+-, 25+-, and 23-gauge UltraVit probes; n = 5 for each gauge). Flow rate was calculated by La...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2016