Conceptual design of a neutron camera for MAST Upgrade.
نویسندگان
چکیده
This paper presents two different conceptual designs of neutron cameras for Mega Ampere Spherical Tokamak (MAST) Upgrade. The first one consists of two horizontal cameras, one equatorial and one vertically down-shifted by 65 cm. The second design, viewing the plasma in a poloidal section, also consists of two cameras, one radial and the other one with a diagonal view. Design parameters for the different cameras were selected on the basis of neutron transport calculations and on a set of target measurement requirements taking into account the predicted neutron emissivities in the different MAST Upgrade operating scenarios. Based on a comparison of the cameras' profile resolving power, the horizontal cameras are suggested as the best option.
منابع مشابه
TRANSP modelling of neutron emissivity on MAST
The aim of this paper is to validate a set of methods to model the measured neutron emission on Mega Amp Spherical Tokamak (MAST) using TRANSP. Neutrons are measured along a set of collimated lines of sight (LoS) at MAST by a Neutron Camera (NC). The neutron emissivity is modeled with TRANSP [1] for different plasma discharges using a selfconsistent data set produced by a data preparation and a...
متن کاملVacuum system upgrade for extended Q-range small-angle neutron scattering diffractometer (EQ-SANS) at SNS
The Extended Q-range Small-angle Neutron Scattering Diffractometer (EQ-SANS) instrument at the spallation neutron source (SNS), Oak Ridge, Tennessee, incorporates a 69 m3 detector vessel with a vacuum system which required an upgrade with respect to performance, ease of operation, and maintenance. The upgrade focused on improving pumping performance as well as optimizing system design to minimi...
متن کاملDesign of a real-time two-color interferometer for MAST Upgrade.
A single chord two-color CO2/HeNe (10.6/0.633 μm) heterodyne laser interferometer has been designed to measure the line integral electron density along the mid-plane of the MAST Upgrade tokamak, with a typical error of 1 × 10(18) m(-3) (∼2° phase error) at 4 MHz temporal resolution. To ensure this diagnostic system can be restored from any failures without stopping MAST Upgrade operations, it h...
متن کاملEstimation of neutron effective dose from DD and DT neutron generators and the design of appropriate shield for standing user
Neutron Generators (NG) are used as a neutron source for different applications. During recent years, major efforts are underway to develop a high yield compact NG. In this way, radiation protection aspects need to be considered during the operation of these high yield NGs. In this paper the neutron effective dose of a NG operator has been calculated using MCNPX Monte Carlo code. The results sh...
متن کاملTitle Design of light element analysis system in BNCT and every NCT
Introduction: The Monte Carlo simulation is used to enhance reliability in the experiments related to nuclear instruments. in addition, that is used to calculate the different components of the neutron and gamma ray fluxes in boron neutron capture therapy(BNCT) and neutron capture (NCT)applications. BNCT is one of the methods in radiotherapy, that is used the neutron beam for ki...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Review of scientific instruments
دوره 85 11 شماره
صفحات -
تاریخ انتشار 2014