Comparison of three different techniques of low-dose-rate seed implantation for prostate cancer
نویسندگان
چکیده
PURPOSE Three different techniques of low-dose-rate seed implantation for prostate cancer have been used since its use started in our hospital. The purpose of this study was to compare the results of the three different techniques. MATERIAL AND METHODS The data of 305 prostate cancer patients who underwent low-dose-rate seed implantation were retrospectively analyzed. Pre-plan technique (n = 27), intraoperative pre-plan technique (n = 86), and interactive plan technique (n = 192) were tried in chronological order. The prescribed dose was set at 145 Gy. RESULTS Median follow-up was 66 months (range: 12-94 months). The 5-year biochemical control rate was 95.5% (pre-plan group: 100%, intraoperative pre-plan group: 90.7%, interactive plan group: 97.0%; p = 0.08). Dosimetric parameters were generally increased from the pre-plan group to the interactive group. The differences in some dosimetric parameters between the planning phase and the CT analysis were significantly reduced with the interactive plan compared to the other techniques. The interactive plan showed a significant reduction of the seed migration rate compared to the two other groups. Acute genitourinary toxicity, acute gastrointestinal toxicity, frequency, and urinary retention increased gradually from the pre-plan period to the interactive plan period. CONCLUSIONS There was no significant difference in biochemical control among the three groups. Dose-volume parameters were increased from the pre-plan technique to the interactive plan technique. However, this may not necessarily be due to technical improvements, since dose escalation was started during the same period. Lower seed migration rates and the smaller differences between the planning phase and CT analysis with the interactive plan technique suggest the superiority of this technique to the two other techniques.
منابع مشابه
Assessment of absorbed dose uncertainty of prostate due to source relocating in brachytherapy by monte carlo method
Brachytherapy, is a method to treat prostate cancer in which a radiation source is placed inside or next to the cancer affected tissues. Purpose of this article is to determine the uncertainty level of received dose in prostate tissue due to the relocation of the placed radiation sources and inflation in prostate after positioning the radiation seeds. To simulate the model 6711 Amersham (activi...
متن کاملComparison of Radiobiological Models for Radiation Therapy Plans of Prostate Cancer: Three-dimensional Conformal versus Intensity Modulated Radiation Therapy
Purpose: In the current study, using different radiobiological models, tumor control probability (TCP) and normal tissue complication probability (NTCP) of radiotherapy plans were calculated for three-dimensional conformal radiation therapy (3D-CRT) and intensity modulated radiation therapy (IMRT) of prostate cancer.Methods and Materials: 10 prostate plans were randomly selected among patients ...
متن کاملThe Relationship between the Different Prostate Intensity Modulated Radiation Therapy Techniques and Patient’s Anatomical Parameters
Introduction: Intensity Modulated Radiotherapy (IMRT) is a common method for treating prostate cancers. Different IMRT methods can apply for irradiating the prostate, but there is not clear that which of these methods can provide better dose distribution for each patient individually. Therefore, the aim of this study was to evaluate the relationship between the different prosta...
متن کاملIodine-125 brachytherapy for localized prostate cancer and urinary morbidity: a prospective comparison of two seed implant methods-preplanning and intraoperative planning.
OBJECTIVES To compare morbidity between two currently used iodine-125 seed implantation techniques for the treatment of localized prostate cancer. METHODS Iodine-125 brachytherapy was used in 300 consecutive men with localized prostate cancer. Two seed implant techniques were used: preplanning, using preloaded needles, and intraoperative planning, using a Mick applicator. A comparison was mad...
متن کاملUse of alpha-1 adrenoceptor antagonists in patients who underwent low-dose-rate brachytherapy for prostate cancer - a randomized controlled trial of silodosin versus naftopidil -
BACKGROUND To evaluate the effect of two different alpha-1 adrenoceptor antagonists on lower urinary tract symptoms in patients who underwent LDR-brachytherapy. METHODS A total of 141 patients who had been clinically diagnosed with localized prostate cancer and underwent LDR-brachytherapy were enrolled. Patients were randomized and allocated to two groups (silodosin 8 mg vs. naftopidil 75 mg)...
متن کامل