A new procedure for the quantitation of C-21 ketosteroids using trifluoromethanesulfonic acid-catalyzed precolumn dansylation and coupled column liquid chromatographic separation, followed by postcolumn 1,1'-oxalyldiimidazole peroxyoxalate chemiluminescence detection is presented. In the simultaneous optimization of chromatographic resolution and chemiluminescence intensity, a coupled column chromatographic system and a stopped-flow system were used. An eluent containing 20 mM phosphate buffer at pH 6.7 accomplished an efficient separation of 3 alpha-hydroxy-5 beta-pregnan-20-one from a mixture containing 10 C-21 ketosteroids. Phosphate buffer also proved to be the most advantageous, among the six buffers tested, for sensitive detection. Experimental design and multivariate data analysis were used to characterize and optimize the postcolumn reaction chemistry in the chromatographic system. A valid full factorial design with excellent predictability showed that the flow rates for both 1,1'-oxalyldiimidazole and hydrogen peroxide were the factors most strongly affecting the sensitivity of the system. The theoretical plate numbers were above 11,000 for all 10 dansylated ketosteroids. The 3 sigma detection limit estimated from 3 alpha-hydroxy-5 beta-pregnan-20-one calibration curve data was 1.6 pmol (n = 4, 125 microL injected) and spiked serum containing 0-74 pmol of this compound showed overall recoveries of 73 +/- 9% (n = 12). Quantitation of 3 alpha-hydroxy-5 beta-pregnan-20-one was finally carried out on 45 serum samples and the results compared to those from a radioimmunoassay (RIA) method. The data acquired with the procedure described in this work compare well with the results from RIA, which confirms the reliability of the new analytical procedure.
منابع مشابه
Automatic semi-microcolumn liquid chromatographic determination of catecholamines in rat plasma utilizing peroxyoxalate chemiluminescence reaction.
A fully automated and highly sensitive method with a semi-microcolumn liquid chromatography system for the determination of rat plasma catecholamines (CAs) was developed. Automated on-line extraction of CAs in diluted plasma using a precolumn packed with strong acidic cation exchange resin was coupled with separation of CAs on a semi-microcolumn (250 x 1.5 mm id). fluorogenic derivatization wit...
متن کاملDevelopment of an immune microanalysis system by use of peroxyoxalate chemiluminescence detection.
We developed an immune microanalysis system incorporating chemiluminescence detection, where the peroxyoxalate chemiluminescence (CL) detection using bis[4-nitro-2-(3,6,9-trioxadecyloxycarbonyl)phenyl]oxalate (TDPO)-hydrogen peroxide (H2O2)-fluorescein isothiocianate (FITC) reaction was newly adopted. The analysis system performed the following three processes on a microchip: immune reaction fo...
متن کاملLiquid chromatographic analysis of glucosamine in commercial dietary supplements using indirect fluorescence detection.
A method of using indirect fluorescence detection is evaluated for the analysis of glucosamine in commercial dietary supplements following chromatographic separation. In this method, the eluting analyte, glucosamine, was detected by monitoring an increase in the fluorescence signal for L-tryptophan (L-Trp) or DL-5-methoxytryptophan (5-MTP) after glucosamine complexed with a copper(II) ion and r...
متن کاملChemiluminescence Determination of Atropine using Luminol-Hemin-H2O2 System
A sensitive and fast chemiluminescence (CL) method has been described for the direct determination of atropine. The method is based on the quenching effect of atropine on the CL signals of the luminol– H2O2 reaction catalyzed by hemin in an alkaline medium. Hemin could strongly enhance the chemiluminescence of the luminol–H2O2 system. The luminophor of the luminol–H2O2–hemin CL system was ident...
متن کاملDirect Chemiluminescence Determination of Oxymorphone Using Potassium Permanganate and Polyphosphoric Acid
Abstract A simple and sensitive chemiluminescence (CL) method was developed for direct quantification of oxymorphone, a µ opioid agonist that is approximately 10 times more potent than morphine. In this method potassium permanganate in polyphosphoric acid was used as CL reagent. Using this method, oxymorphone can be determined over the concentration ranges 13.5-337.8 ng mL-1 and 0.34-6.76...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Analytical chemistry
دوره 70 23 شماره
صفحات -
تاریخ انتشار 1998