Accuracy of intraocular lens power calculations using the Zeiss IOL master. A prospective study.
نویسندگان
چکیده
PURPOSE Partial Coherence Interferometry (PCI) is a fast, noncontact method to calculate lens implant power for cataract surgery. It has been reported as a potentially more accurate method than ultrasound biometry. Prospective study of the refractive outcomes of a consecutive series of patients undergoing phacoemulsification surgery with preoperative biometry by both ultrasound A-scan and PCI. METHODS A series of 50 eyes of 35 patients underwent small-incision phacoemulsification cataract surgery and lens implantation by one single surgeon. All patients had preoperative biometry performed by both ultrasound using the Sonomed and IOL Master optical biometry. The IOL Master results were included in the SRK II formula to calculate the lens implant power. Postoperative refractive assessment was performed 4 weeks after surgery. RESULTS The mean difference in axial length between ultrasound and optical biometry was 0.2 mm. The IOL Master measures a longer axial length. The mean keratometric power using the Javal instrument was 43.4 D and for the Zeiss IOL Master it was 42.9 D. At the week 4 postsurgery assessment, the overall refractive outcome was in the range of +/- 1D. Five patients were unable to undergo PCI biometry due to the density of cataract. CONCLUSIONS Intraocular lens power calculations using the Zeiss IOL Master are easy to perform and result in excellent refractive outcomes. A-scan biometry is still needed in case of mature cataract.
منابع مشابه
مقایسهی کراتومتری پنتاکم وکراتومتری IOL Master در محاسبهی لنز داخل چشمی افراد با قرنیهی طبیعی
Background and Objective: Proper method and machine for corneal evaluation is an important factor in many anterior segment interventions. This study was performed to compare the mean keratometry (K) readings obtained with an IOL Master and Pentacam for intraocular lens power calculation in normal subjects with no history of refractive surgery. Materials and Methods: Mean K values were obtained ...
متن کاملComparison of IOL--master and ultrasound biometry in preoperative intra ocular lens (IOL) power calculation.
Postoperative refractive outcome largely depends on the accuracy of calculating power of implanted IOL. Lens power calculation can be done by conventional ultrasound biometry and partial coherence laser interferometry (IOL Master). The aim was to compare the accuracy of IOL power calculations using conventional ultrasound biometry and partial coherence laser interferometry.40 eyes were included...
متن کاملPrediction of Refractive Outcome of Second Eye with Partial Adjustment of Intraocular Lens Power of the First Eye
Background and Objective: This study aimed at comparing the results of refractive cataract surgery in patients undergoing sequential surgeries in both eyes. Considering the preoperative refraction and final refraction of the first eye, it is possible to correct the refrative result of cataract surgery using the adjustment of the second eye intraocular lens (IOL) power. Materials and Methods: T...
متن کاملPrediction error and accuracy of intraocular lens power calculation in pediatric patient comparing SRK II and Pediatric IOL Calculator
BACKGROUND Despite growing number of intraocular lens power calculation formulas, there is no evidence that these formulas have good predictive accuracy in pediatric, whose eyes are still undergoing rapid growth and refractive changes. This study is intended to compare the prediction error and the accuracy of predictability of intraocular lens power calculation in pediatric patients at 3 month ...
متن کاملIntraocular lens calculation accuracy limits in normal eyes.
PURPOSE To quantify the current accuracy limits, analyze the residual errors, and propose the next steps for prediction accuracy improvements. SETTING Eye hospitals in Germany, Denmark, and Austria. METHOD Numerical ray tracing using manufacturer's intraocular lens (IOL) data (vertex radii, central thickness, refractive index) was used for all calculations. Postoperative lens position was p...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Bulletin de la Societe belge d'ophtalmologie
دوره 281 شماره
صفحات -
تاریخ انتشار 2001