Digital pupillometry and centroid shift changes after cataract surgery.
نویسندگان
چکیده
PURPOSE To compare postoperative changes in apparent photopic and mesopic pupil size and centration in relation to cornea reflection landmarks after cataract surgery. SETTING LaserVision.gr Clinical and Research Eye Institute, Athens, Greece. DESIGN Prospective consecutive case study. METHODS Pupils were imaged for pupil size and corneal vertex location before and 1-month after cataract surgery. Digital analysis of pupil images was used to determine the Cartesian coordinates (nasal-temporal, horizontal axis, superior-inferior, vertical axis) of the first Purkinje reflection point (approximating the corneal intersection of the visual axis [corneal vertex]) to the pupil geometric center (approximating the corneal intersection of the line of sight [corneal apex]). Pupil size changes were measured, and the correlation between vertex-to-apex shift changes and postoperative pupil centroid shift was evaluated. RESULTS The study evaluated 40 eyes. The pupil size (diameter) change corresponded to a relative reduction of -9.8% for photopic pupils and -9.1% for mesopic pupils; the difference was statistically significant (P = .045 and P = .011, respectively). Also, there was a reduction in the centroid shift (all eyes) from a mean of 0.12 mm preoperatively to 0.05 mm postoperatively as a result of the postoperative minus temporal horizontal difference between the corneal vertex and the apex. CONCLUSIONS Cataract extraction surgery appears to affect pupil size and centration. Specifically, a smaller pupil and less temporal shift were recorded. These data may have clinical relevance in targeted intraoperative intraocular lens centration. FINANCIAL DISCLOSURE Dr. Kanellopoulos is a consultant to Alcon Surgical, Inc., Wavelight Laser Technologie AG, Allergan, Avedro, Inc., and i-Optics Corp. No author has a financial or proprietary interest in any material or method mentioned.
منابع مشابه
Interpretation of aberrometry measurements in cataract surgery.
PURPOSE To discuss the use of wavefront measurements generated from the NIDEK OPD-Scan II and OPD-Station for cataract surgery. METHODS Case examples are presented along with information and relevant clinical data obtained from the OPD-Scan II aberrometer and OPD-Station software. All eyes underwent corneal topography, wavefront aberrometry, autorefraction, keratometry, and pupillometry measu...
متن کاملInvestigation of visual acuity and residual refractive error after cataract surgery in patients with senile cataract by phacoemulsification
Background and Aim: Vision improvement and reduction of refractive errors are considered as important goals of cataract surgery. The purpose of this study was to evaluate residual refractive errors after cataract surgery in the patients with senile cataract in Shahid Rahimi Hospital in Khorramabad City between 2017 and 2018. Material and Methods: This cross-sectional study included 178 patients...
متن کاملکاربرد لنزهای داخل چشمی در جراحی کاتاراکت و عوامل تأثیرگذار بر دید بیمار
Introduction: With the growing and rapid development of refractive surgery, researches focus increasingly on improvement of visual quality after cataract surgery. Intraocular lenses (IOLs) were a successful effort in the field of cataract surgery. Despite significant advances in cataract surgery, several complications related to surgical technique and IOL design after surgery can cause vision c...
متن کاملLong-term renormalization of chromatic mechanisms following cataract surgery.
The optical density of the human crystalline lens progressively increases with age, the greatest increase in the visible spectrum being at short wavelengths. This produces a gradual shift in the spectral distribution of the light reaching the retina, yet color appearance remains relatively stable across the life span, implying that the visual system adapts to compensate for changes in spectral ...
متن کاملCataract Surgery and Aqueous Humor pH Changes
Purpose: To compare aqueous humor pH changes during femtosecond (FS) laser-assisted cataract surgery with conventional cataract surgery. Results: The mean pH was 6.53 ± 0.09 (range 6.42-6.70) and 7.42 ± 0.07 (range 7.28-7.48) in Groups 1 and 2, respectively. Differences between groups in this parameter were statistically significant (p < 0.001). Conclusions: Photo disruption process in the femt...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of cataract and refractive surgery
دوره 41 2 شماره
صفحات -
تاریخ انتشار 2015