Correcting Astigmatism with Acrysof Toric Lenses (SN60T3 to SN60T9) in Cataract Surgery

نویسنده

  • Shahab Heidarian
چکیده

Purpose: The objective of this study was to evaluate the outcome of Acrysof Toric intraocular lenses (IOLs) implantation in cataract surgery for the correction of regular corneal astigmatism. Methods: Twenty eyes of 16 patients with cataract and regular corneal astigmatism of 1.00-4.00 diopter (D) underwent surgery. Depending on the amount of corneal astigmatism, an Acrysof Toric IOL of type SN60T3, SN60T4, SN60T5, SN60T6, SN60T7, SN60T8 or SN60T9 was implanted. Studied parameters before and after surgery included uncorrected visual acuity (UCVA), best corrected visual acuity (BCVA), residual refractive astigmatism, change in corneal astigmatism, IOL rotation, and spectacle independence for distance vision. Results: At six months after surgery, all eyes (100%) had a UCVA of 20/32 or better and 80% had a UCVA of 20/25 or better. Spectacle independence for distance vision was 85% in the studied eyes. The change in corneal astigmatism ranged between 0.25 and 0.5 D in all eyes. The residual astigmatism was 0.75 D or less in 100% of the cases and 0.0 to 0.5 D in 90% of the eyes. IOL rotation was zero degrees in 65% of the eyes, 4° or less in 90% of the eyes, and 5° or more in 10% of the eyes by six months after surgery. Conclusion: Using Acrysof Toric IOLs (SN60T3 to SN60T9) during cataract surgery for patients who have regular corneal astigmatism of 1.0 to 4.0 D is an effective, predictable, and rather stable option for correcting astigmatism.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Results of the AcrySof Toric intraocular lenses implantation

BACKGROUND The expectations of post-removal cataract surgery patients are extremely high, and best vision acuity is expected. The best refractive results are influenced by two factors - cataract surgical removal and the corneal astigmatism correction. Currently, the two most often applied corneal astigmatism removal methods are laser surgery and toric intraocular lens implantation, with the lat...

متن کامل

Rotational stability of the AcrySof SA60TT toric intraocular lenses: A cohort study

BACKGROUND To evaluate the rotational stability of the three types of AcrySof SA60TT toric intraocular lenses (Alcon, Switzerland) in cataract surgery after the first postoperative week. METHODS A retrospective study of 44 eyes in 33 patients. All patients underwent similar uncomplicated phacoemulsification cataract surgery. Seven eyes with corneal astigmatism of less than 1.5 D were implante...

متن کامل

Comparative rotational stability of single-piece open-loop acrylic and plate-haptic silicone toric intraocular lenses.

PURPOSE To prospectively compare the early rotational stability of AcrySof SN60T toric intraocular lenses (IOLs) with that in a retrospective series of AA4203 toric IOLs. SETTING Private practice, Los Altos, California, USA. METHODS One hundred consecutive eyes with an AcrySof SN60T(3, 4, or 5) toric IOL were compared with a consecutive series of 90 AA4203 (TL or TF) toric IOLs. The same su...

متن کامل

Long-Term Efficacy and Rotational Stability of AcrySof Toric Intraocular Lens Implantation in Cataract Surgery

PURPOSE To evaluate the long-term efficacy and rotational stability of the AcrySof toric intraocular lens (IOL) in correcting preoperative astigmatism in cataract patients. METHODS This prospective observational study included 30 eyes from 24 consecutive patients who underwent implantation of an AcrySof toric IOL with micro-coaxial cataract surgery between May 2008 and September 2008. Outcome...

متن کامل

Which Keratometer is Most Reliable for Correcting Astigmatism with Toric Intraocular Lenses?

PURPOSE To evaluate the accuracy of preoperative keratometers used in cataract surgery with toric intraocular lens (IOL). METHODS Twenty-five eyes received an AcrySof toric IOL implantation. Four different keratometric methods, a manual keratometer, an IOL master, a Pentacam and an auto keratometer, were performed preoperatively in order to evaluate preexisting corneal astigmatism. Difference...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017