Dynamic Lorentz Force Compensation with a Fast Piezoelectric Tuner
نویسنده
چکیده
Superconducting cavities are highly susceptible to small changes in resonance frequency due to their narrow bandwidth. At the proposed linac for the TESLA Linear Collider [1] the frequency changes resulting from mechanical deformations caused by Lorentz force detuning of the pulsed cavities will be of the order of the cavity bandwidth at the design operating gradient close to 25 MV/ m. The additional power required for field control is of the order of 10 % and will be intolerably high for the planned upgrade to 35 MV/m which appears to be feasible in the near future. While passive stiffening of the cavities is already applied to the present cavity design, the further reduction of the Lorentz force detuning constant is technically challenging. Therefore we propose an active scheme which reduces the timevarying Lorentz force detuning to much less than one cavity bandwidth. If successful, the scheme will improve the power efficiency of the TESLA linac significantly.
منابع مشابه
Compensating Microphonics in SRF Cavities to Ensure Beam Stability for Future Free-Electron-Lasers
In seeded High-Gain-Harmonic-Generation free electron lasers or energy recovery linear accelerators the requirements for the bunch-to-bunch timing and energy jitter of the beam are in the femtosecond and per mill regime. This implies the ability to control the cavity radiofrequency (RF) field to an accuracy of 0.02◦ in phase and up to 1·10-4 in amplitude. For the planned BESSY-FEL it is envisag...
متن کاملOn the Pressure Compensation for the B-cell Cavity in the MARK II Cryostat
I. How Tuner Works The B-cell superconducting cavity is tuned by mechanically stretching the cavity along the beam line relative to the cryostat. The drive train consists of a stepping motor followed by a 4.38:1 dual leverage mechanism terminating in a dual parallel flex hinge arrangement (tuner flexure) with mechanical advantage of 3.9:1. The flexure is patterned after the proposed LANL PILAC ...
متن کاملDynamic modeling and nonlinear vibration simulation of piezoelectric micro-beam in self sensing mode of atomic force microscope
Nowadays, atomic force microscope is considered as a useful tool in the determination of intermolecular forces and surface topography with the resolution of nanometers. In this kind of microscope, micro cantilever is considered as the heart of the microscope and is used as a measuring tool. This paper is aimed towards investigating the behavior of a piezoelectric micro cantilever with a triang...
متن کاملEffects of Fluid Environment Properties on the Nonlinear Vibrations of AFM Piezoelectric Microcantilevers
Nowadays, atomic-force microscopy plays a significant role in nanoscience and nanotechnology, and is widely used for direct measurement at atomic scale and scanning the sample surfaces. In tapping mode, the microcantilever of atomic-force microscope is excited at resonance frequency. Therefore, it is important to study its resonance. Moreover, atomic-force microscopes can be operated in fluid e...
متن کاملApplication of Piezoelectric and Functionally Graded Materials in Designing Electrostatically Actuated Micro Switches
In this research, a functionally graded microbeam bonded with piezoelectric layers is analyzed under electric force. Static and dynamic instability due to the electric actuation is studied because of its importance in micro electro mechanical systems, especially in micro switches. In order to prevent pull-in instability, two piezoelectric layers are used as sensor and actuator. A current amplif...
متن کامل