Dual-Controlled Indirect Cooling Refrigerator/Freezer Using Two Capillary Tubes and an Air Flow Switching System
نویسندگان
چکیده
The dual~controlled refrigeration system is devised to enhance the energy efficiency and basic performance of an indirect cooling household refrigerator/freezer. In order to alternately serve the fresh food and freezer compartment with a conventional simple refrigeration cycle, two capillary tubes and on/off valves are adopted. The air flow switching system, which is composed of two fans and dampers, is used to provide air flow for each compartment The motor-driven on/off dampers are employed to switch the circulating path of air flowing through each compartment. The cycle and air flow switching system are controlled on the basis of compartment temperature. In the present investigation, the 510L prototype unit is a modification of a conventional refrigerator/freezer. The cycle matching and performance test is performed at 30 OC ambient temperature. The energy consumption test reveals that compared to the conventional system, the energy consumption of the present refrigeration system is reduced by about 9%. Moreover, the cooling speed test result shows that with the present refrigeration system, the refrigeration and freezing time become about 10 minute shorter than the conventional system. R-12 was used for this research.
منابع مشابه
A New Control System of a Household Refrigerator-Freezer
This paper will present the structure of the new system, the control scheme and its performance test results. In this new system, the damper in the conventional refrigerator is replaced by an additional cooling fan Thus, it uses two cooling fans: one (F-fan) is to provide cooled air for freezing compartment (F-compartment) and the other (R-fan) is for refrigerating compartment (R-compartment), ...
متن کاملStrategies for Improving Temperature Control and Energy Use in Household Refrigerators
Conventional control of household refrigerators is typically accomplished with simple, single-sensor control systems. Though cost-effective this approach allows temperature dependencies to exist between compartments, producing non-optimal energy consumption. In order to study the performance of the conventional refrigerator a computer model was developed. Analytical results were generated to de...
متن کاملThermodynamic Optimization of Household Refrigerator Using Propane –Butane as Mixed Refrigerant
A household refrigerator designed to work with R-134a was used as an investigation unit to assess the prospect of using mixed refrigerants. The recital of the refrigerator using mixed refrigerant was investigated and compared with the performance of refrigerator when R-134a was used as refrigerant. The effect of condenser temperature and evaporator temperature on COP, refrigerating effect was i...
متن کاملInvestigation of Using Nonazeotropic Refrigerant Mixture as the Replacement for R12
This paper investigates the effects of nonazeotropic refrigerant mixtures (NARMs) as replacement of CFCs. The thermodynamic propert1es of NARM R22/R142b which is harmless to ozone layer are analyzed. The tests about water-to-water heat pump and dual-evaporator refrigerator-freezer using R22/R142b as alternative to R12 are introduced. The test results show R22/Rl42b is of energy conserving effec...
متن کاملPerformance Comparison of Domestic Refrigerator using HFC134a and HFC134a/HC Refrigerant Mixture
An experimental performance comparison study on domestic refrigerator system was conducted and compared with HFC134a and M09 (HFC134a and HC blend (containing 55.2%HC600a and 44.8%HC290 by weight)) mixture refrigerant. The domestic refrigerator system was initially designed to operate with HFC134a.Experimental results showed that the refrigeration capacity of the refrigerant M09 mixture system ...
متن کامل