Non-linear dynamical analyses of transient surface temperature fluctuations during subcooled pool boiling on a horizontal disk

نویسندگان

  • Vijaykumar Sathyamurthi
  • Debjyoti Banerjee
چکیده

0017-9310/$ see front matter 2009 Elsevier Ltd. A doi:10.1016/j.ijheatmasstransfer.2009.06.023 * Corresponding author. Tel.: +1 979 845 4500; fax E-mail address: [email protected] (D. Banerjee The class of dynamics in pool boiling on a large-size heater is assessed under subcooled pool boiling conditions. Transient surface temperature measurements are obtained using surface micro-machined K-type thin film thermocouples (TFT) in 10 C subcooled pool boiling experiments on a 62.23 mm diameter silicon wafer using PF-5060 as the test liquid. Surface temperature data is obtained at each steady state condition to generate the boiling curve. The fraction of false-nearest neighbors, recurrence plots and space–time separation plots are obtained using the TISEAN package. The correlation dimension is then estimated from the re-constructed phase space data using a naïve algorithm. The correlation dimension varies from 11.2 to 11.5 near onset of nucleate boiling (ONB), to 7–10 in fully developed nucleate boiling (FDNB) 7–9 near critical heat flux (CHF) condition, and from 6.6 to 7.7 in film boiling. False-nearest neighbor estimates and recurrence plots show that nucleate boiling may be dominated by statistical processes near ONB and in partial nucleate boiling (PNB). In contrast, FDNB, CHF and film boiling seem chaotic and governed by deterministic processes. 2009 Elsevier Ltd. All rights reserved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Effect of Linear Change of Tube Diameter on Subcooled Flow Boiling and Critical Heat Flux

One of the major industry problems is the flow boiling, where reaching to the critical heat flux (CHF) condition can lead to a temperature jump and damage of the systems. In the present study, the effects of a uniform change in tube diameter on subcooled flow boiling and CHF was numerically investigated. The Euler-Euler model was used to investigate the relationship between the two liquid and v...

متن کامل

Simulation of Subcooled Flow Boiling Occurring in Internal Combustion Engine Water Jacket by Numerical Modeling in a Channel with Hot Spot

Boiling heat transfer always has been proposed as a solution for enhancing heat transfer between the fluid and solid surfaces. Subcooled flow boiling is one of the mechanisms that occur in Internal Combustion Engine water jacket in which high amounts of heat is transferred. In this research, it has been tried to simulate subcooled flow boiling in a geometry similar to coolant channel inside the...

متن کامل

Subcooled two-phase flow boiling in a microchannel heat sink: comparison of conventional numerical models

Subcooled flow boiling in multi-microchannels can be used as an efficient thermal management approach in compact electrical devices. Highly subcooled flow boiling of HFE 7100 is studied in two microchannel heat sinks to choose a proper numerical model for simulating boiling flows in microchannels. Results of five different numerical models, including Volume of Fluid (VOF), Eulerian boiling, Eul...

متن کامل

Evaluation of Exerting Force on the Heating Surface Due to Bubble Ebullition in Subcooled Flow Boiling

Vibration characteristics of subcooled flow boiling on thin and long structures such as a heating rod were recently investigated by the author. The results show that the intensity of the subcooled boiling-induced vibration (SBIV) was influenced strongly by the conditions of the subcooling temperature, linear power density and flow velocity. Implosive bubble formation and collapse are the main n...

متن کامل

Experimental measurement of heat transfer coefficient and mass of deposited CaSO4 in subcooled flow boiling condition

Fouling is a common, fundamental and costly problem in heat transfer systems, which reduces thermal efficiency of equipment, increases the energy loss and causes strong damage to the heat transfer equipment in various industries. The main causes of fouling on the heat transfer surfaces are salts with inverse temperature-solubility in the fluid which calcium sulfate is one of the most important ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009