99mTc-DTPA Renal Dynamic Imaging Method May Be Unsuitable To Be Used as the Reference Method in Investigating the Validity of CDK-EPI Equation for Determining Glomerular Filtration Rate

نویسندگان

  • Peng Xie
  • Jian-Min Huang
  • Xiao-Mei Liu
  • Wei-Jie Wu
  • Li-Ping Pan
  • Hai-Ying Lin
چکیده

OBJECTIVE To compare the measurements of glomerular filtration rate (GFR) determined by (99m)Tc-diethylene triamine pentaacetic acid ((99m)Tc-DTPA) renal dynamic imaging with those estimated by Chronic Kidney Disease Epidemiology Collaboration (CDK-EPI) equation and to identify a more accurate measurement of GFR of chronic kidney disease (CKD) patients in clinical practice. METHODS The GFR was determined simultaneously by 3 methods: (a) dual plasma sample clearance method (tGFR); (b) renal dynamic imaging method (dGFR); (c) CDK-EPI equation (eGFR). The tGFR was employed as the reference method. The correlation, regression, and limit of agreement of dGFR and eGFR were used to demonstrate the validity of the two methods. The comparison of bias, precision, and accuracy between dGFR and eGFR was analyzed to identify the most suitable method. The analysis of bias, precision and accuracy was repeated after stratifying patients by a measured tGFR cutpoint of 60 ml·min(-1)·(1.73 m(2))(-1). RESULTS A total of 149 patients were enrolled. Both dGFR and eGFR correlated well with tGFR and the regression equation of dGFR and eGFR against tGFR was respectively Y = -4.289+0.962X (r = 0.919; RMSE = 14.323 ml.min(-1). (1.73 m(2))(-1); P<0.001) and Y = 2.462+0.914X (r = 0.909; RMSE = 15.123 ml.min(-1). (1.73 m(2))(-1); P<0.001). In addition, Bland-Altman analysis showed preferable agreement between the two methods and the reference method. The comparison revealed that eGFR, compared with dGFR, showed better performance on bias and 50% accuracy and similar performance on other indexes in the whole cohort and the lower-GFR subgroup, whereas in the higher-GFR subgroup the difference of the two methods was not significant in all parameters. CONCLUSIONS Although both CDK-EPI equation and renal dynamic imaging can be used to determine the GFR of CKD patients, CDK-EPI equation is more accurate than renal dynamic imaging. As a result, (99m)Tc-DTPA renal dynamic imaging may be unsuitable to be used as the reference method in investigating the validity of CDK-EPI equation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determining an accurate method to estimate GFR in renal transplant recipients with stable serum creatinine levels

Introduction:Detecting renal allograft dysfunction early will allow timely diagnosis and treatment. There is no objective recommendation by national kidney societies for glomerular filtration rate (eGFR) estimation in post-transplant setting. 99mTc-DTPA Technetium-99m Diethylene triamine penta acetic acid) renogram can identify early renal dysfunction much before ser...

متن کامل

Determination of glomerular filtration rate using technetium-99m-DTPA with differing degrees of renal function.

UNLABELLED Glomerular filtration rate (GFR) is an important index of renal function. Twenty-four-hour creatinine clearance overestimates GFR in patients with poor renal function. Inulin and iothalamate clearances are accepted reference standards for determining GFR but are expensive and laborious. We have previously reported that GFRs obtained by measuring the disappearance of 99mTc-DTPA from u...

متن کامل

Glomerular filtration rate measured by 99mTc‐DTPA renal dynamic imaging is significantly lower than that estimated by the CKD‐EPI equation in horseshoe kidney patients

AIM Gate's glomerular filtration rate (gGFR) measured by (99m) Tc-DTPA renal dynamic imaging and estimated GFR (eGFR) estimated by the Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI) equation are two indexes used to evaluate renal function. However, little is known about whether gGFR can be used to accurately assess renal function in horseshoe kidney (HSK) patients with renal fusion...

متن کامل

A more accurate method acquirement by a comparison of the prediction equations for estimating glomerular filtration rate in Chinese patients with obstructive nephropathy

BACKGROUND Researchers have developed several equations to predict glomerular filtration rate (GFR) in patients with chronic kidney diseases (CKD). However, there are scarcely any studies performed to discern the best equation to estimate GFR in patients with pure obstructive nephropathy. In present study, we assessed the suitability of six prediction equations and compared their performance in...

متن کامل

Using Mathematical Algorithms to Modify Glomerular Filtration Rate Estimation Equations

BACKGROUND The equations provide a rapid and low-cost method of evaluating glomerular filtration rate (GFR). Previous studies indicated that the Modification of Diet in Renal Disease (MDRD), Chronic Kidney Disease-Epidemiology (CKD-EPI) and MacIsaac equations need further modification for application in Chinese population. Thus, this study was designed to modify the three equations, and compare...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2013