On-line monitoring of nitrogenase activity in cyanobacteria by sensitive laser photoacoustic detection of ethylene.

نویسندگان

  • H Zuckermann
  • M Staal
  • L J Stal
  • J Reuss
  • H S Te Lintel
  • F Harren
  • D Parker
چکیده

A new and extremely sensitive method for measuring nitrogenase activity through acetylene reduction is presented. Ethylene produced by nitrogenase-mediated reduction of acetylene is detected by using laser photoacoustics (LPA). This method possesses a detection limit making it 3 orders of magnitude more sensitive than traditional gas chromatographic analysis. Photoacoustic detection is based on the strong and unique absorption pattern of ethylene in the CO(inf2) laser wavelength region (9 to 11 (mu)m). The high sensitivity allowed on-line monitoring of nitrogenase activity in a culture of the heterocystous cyanobacterium Nodularia spumigena, which was isolated from a water bloom in the Baltic Sea. This setup makes it unnecessary to take subsamples from the culture and avoids long incubations in sealed vials. The fast response of the LPA technique allows measurement of real-time dynamic changes of nitrogenase activity. The method was used to analyze in vivo saturation of nitrogenase by acetylene in N. spumigena. It is demonstrated that 20% acetylene does not saturate nitrogenase and that the degree of saturation depends on light intensity. With concentrations of acetylene as low as 2.5% it is possible to assess the degree of saturation and to extrapolate to total nitrogenase activity. In N. spumigena nitrogenase activity becomes independent of light intensity above 20 to 80 (mu)mol of photons m(sup-2) s(sup-1) at 20% O(inf2).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design and Application of a Photoacoustic Sensor for Monitoring the Laser Generated Stress Waves in Optical Fiber

Measurement of stress transients generated by a 400ns pulsed HF laser in an infrared fluoride glass fiber has been made using fast time – response piezoelectric film transducer. Acoustic signals up to 12 mV with frequencies ranging in megahertz generated by 21 mJ laser pulse when passed through the fiber axis in the linear region. It is shown that useful information such as onset of non - linea...

متن کامل

Field detection of CO and CH4 by NIR 2f modulation laser spectroscopy

  A novel compact fiber-coupled NIR system based on a DFB diode laser source is employed as a portable and sensitive gas sensor for trace detection of combustion pollutant molecules. We demonstrate the performance of such an NIR gas sensor by tracing the absorption lines of CO and CH4 using 2f-WMS technique at moderate temperature of T ~ 600°C in the recuperator channel of an industrial furnace...

متن کامل

trans-Resveratrol and grape disease resistance. A dynamical study by high-resolution laser-based techniques.

Two modern laser-based techniques were synchronously applied to study the dynamics of the trans-resveratrol activity in Botrytis cinerea-infected grapes. Direct analysis of trans-resveratrol in both infected and noninfected grapes (Vitis vinifera, Aledo variety) was performed by using an analytical technique incorporating laser desorption coupled with laser resonant ionization and time-of-fligh...

متن کامل

The advantage of using a diode laser instead of a Q-switched laser in photoacoustic imaging of tissues

Photoacoustic (PA) imaging of biological tissues using laser diodes instead of conventional Q switched pulsed systems provides an attractive alternative for biomedical applications. However, the relatively low energy of laser diodes operating in the pulsed regime, results in generation of very weak acoustic waves, and low signal-to-noise ratio (SNR) of the detected signals. This problem can be ...

متن کامل

CO2 LASER-PHOTOACOUSTIC STUDY OF EXHALED BREATH PRODUCED BY ELECTRONIC vs. TRADITIONAL CIGARETTES

CO2 laser-photoacoustic technology was used to investigate the suitability of ethylene as biomarker for active smoking with electronic cigarettes (E-cigarettes) vs. traditional cigarettes (T-cigarettes). Higher levels of ethylene in the composition of breath after T-cigarettes inhalation was found in comparison with the inhalation with E-cigarettes. The goal of this study was to explore and ver...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Applied and environmental microbiology

دوره 63 11  شماره 

صفحات  -

تاریخ انتشار 1997