Real-time three-dimensional transesophageal echocardiography is useful for percutaneous closure of multiple secundum atrial septal defects.

نویسندگان

  • Chun Zhang
  • Zhian Li
  • Jin Xu
چکیده

INTRODUCTION The purpose of this study was to investigate the clinical value of real-time three-dimensional transesophageal echocardiography (RT-3D-TEE) for percutaneous transcatheter closure of multiple secundum atrial septal defects (ASDs) using a Chinese domestic occluder device. METHODS From July 2008 to September 2011, 37 patients (mean age 28.4 ± 9.7 years; 24 females) with multiple secundum ASDs underwent percutaneous transcatheter closure in our institution with custom-made occluder devices. RT-3D-TEE was used to clarify the diagnosis and to help determine the operation scheme before the procedure, for real-time monitoring and guiding the operation during the procedure, and for evaluating the result shortly after the procedure. RESULTS The custom-made atrial septal occluders were successfully implanted in 36 patients under RT-3DTEE guidance. Twenty-seven patients were implanted with two devices and 9 patients with a single device. In two patients where the distance between the two defects was less than 7 mm (5.5 mm and 6 mm), double occluder devices were also successfully implanted. One patient underwent surgery for the complication of unstable occluder and increased residual shunt after closure. No other severe complications were observed. CONCLUSIONS RT-3D-TEE provides reliable diagnostic evidence of multiple ASDs and can help the clinician to select an appropriate operation scheme according to the number and morphology of multiple defects prior to percutaneous transcatheter closure. It also allows for proper positioning of the devices during the procedure and provides an effective means of evaluating the success of the procedure. For two devices to be implanted simultaneously in multiple ASDs, the usual requirement for the distance between the two defects may differ between our domestically made devices and the Amplatzer occluder.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Percutaneous closure of multiple secundum atrial septal defects using 3 amplatzer atrial septal occluder devices: evaluation by live transthoracic 3-dimensional echocardiography.

A previously healthy 12-year-old boy was admitted to the hospital with acute pneumonitis. On admission, a heart murmur was detected. The transthoracic echocardiogram showed multiple secundum atrial septal defects with left-toright shunt and signs of right ventricular volume overload. He underwent right cardiac catheterization and transesophageal echocardiogram (transesophageal echocardiography)...

متن کامل

Successful percutaneous closure of a residual atrial septal defect due to device failure.

A 39-year-old woman underwent uneventful percutaneous occlusion of an ostium secundum atrial septal defect (ASD) with a 22 mm Ultrasept ASD Occluder®. Transesophageal echocardiography (TEE) performed two years after implantation revealed a de novo residual left-to-right shunt through the correctly implanted device. Three-dimensional transesophageal echocardiography (3D TEE) further clarified th...

متن کامل

Live/Real Time Three-Dimensional Trans Esophageal Echocardiographic Findings in Amplatzer ASD Closure Devices in Adults

Six female patients aged from 19 to 73 years, with ostium secundum atrial septal defect underwent closure procedure with Amplatzer septal occluder device. Three-dimensional Echocardiography (3D-TEE) was done during the procedure or one day after the procedure. 3D-TEE provides incremental value over Two- dimensional trans-esophageal echocardiography in measuring Amplatzer septal occluder disc si...

متن کامل

Cryptogenic stroke after percutaneous closure of an atrial septal defect.

We present the case of a patient who underwent a percutaneous secundum atrial septal defect (ASD II) closure with an undersized septal occluder device. One week and one month later she experienced two transient ischemic attacks. Three-dimensional transesophageal echocardiography (TEE) revealed a residual patent foramen ovale (PFO) with a positive Valsalva bubble test. She underwent a second pro...

متن کامل

A failed case of percutaneous septal closure of fenestrated atrial septal defect.

A patient presenting with a history of palpitation and exertional dyspnea was initially diagnosed with two separate secundum-type atrial septal defects by transesophageal echocardiography. Subsequent transesophageal echocardiography, after failure of closure with two separate closure devices, showed another defect and an ongoing left to right shunt. During surgery, more defects were observed. T...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Hellenic journal of cardiology : HJC = Hellenike kardiologike epitheorese

دوره 55 6  شماره 

صفحات  -

تاریخ انتشار 2014