Posterior instrumentation after a failed balloon kyphoplasty in the thoracolumbar junction: a case report

نویسندگان

  • David Cumming
  • Thomas Pagonis
  • Ryan Wood
چکیده

INTRODUCTION Balloon kyphoplasty provides symptomatic relief of vertebral compression fractures in elderly patients. Peri-operative complications are rare; however, they can potentially be devastating. To the best of our knowledge, complications during balloon kyphoplasty have not been described previously in published case reports. CASE PRESENTATION A 66-year-old man who was a farmer of Caucasian origin presented with a 6-month history of back pain after a fall. We discovered a significant T12 wedge compression fracture, so we performed a T12 balloon kyphoplasty. Approximately 2 weeks after being discharged from our hospital, the patient presented with increasing back pain. He presented for a second time with excruciating pain on the left side of his thoracolumbar region, so he was admitted to our ward. X-rays did not show any further fractures or compromise, but magnetic resonance imaging showed extensive edema in the T11 and L1 vertebral bodies as well as fluid tracking from the T11-T12 disc into the vertebral body. Nine days after being discharged, the patient presented to the outpatient clinic with severe back pain. Magnetic resonance imaging at that visit showed edema at the levels above and below the T11/T12 disc. He was put into a brace and given 300mg of morphine, which did not provide any pain resolution. Posterior instrumentation from T9 to L2 (pedicle fixation of T9-T10 as well as L1-L2, rods in between and a crosslink above T11-T12) was performed as the final treatment, and the patient was discharged uneventfully. CONCLUSION Patients presenting with residual pain over a previous balloon kyphoplasty level should raise high suspicion for a fracture or complication involving the levels above and/or below the balloon kyphoplasty. The best way to treat fractures that develop after a failed balloon kyphoplasty is to instrument and fuse posteriorly. Our present case report shows that a high level of suspicion for possible new fractures should be maintained for all similar cases.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Safe surgical technique: cement-augmented pedicle screw instrumentation and balloon-guided kyphoplasty for a lumbar burst fracture in a 97-year-old patient

BACKGROUND During the last few years, an increasing number of unstable thoracolumbar fractures, especially in elderly patients, has been treated by dorsal instrumentation combined with a balloon kyphoplasty. This combination provides additional stabilization to the anterior spinal column without any need for a second ventral approach. CASE PRESENTATION We report the case of a 97-year-old male...

متن کامل

Is additional balloon Kyphoplasty safe and effective for acute thoracolumbar burst fracture?

BACKGROUND Burst fracture is a common thoracolumbar injury that is treated using posterior pedicle instrumentation and fusion combined with transpedicular intracorporeal grafting after reduction. In this study, we compared the outcome of these two techniques by using radiologic imaging and functional outcome. METHODS Sixty-one patients with acute thoracolumbar burst fracture were operated wit...

متن کامل

Prone position in balloon kyphoplasty leads to no secondary vertebral compression fractures in osteoporotic spine – a MRI study

PURPOSE Vertebral compression fractures are the most common fractures in the elderly. Long lasting pain and deformity is responsible for consecutive impairment with markedly reduced life quality, increased morbidity and mortality. The beneficial effects of balloon kyphoplasty are verified in many studies. Subsequent fracture risk is not finally clarified, cement related risks and deformity rela...

متن کامل

Balloon vertebroplasty with calcium phosphate cement augmentation for direct restoration of traumatic thoracolumbar vertebral fractures.

STUDY DESIGN A human cadaveric model was used to evaluate balloon vertebroplasty in traumatic vertebral fractures. OBJECTIVES To assess the feasibility and safety of balloon vertebroplasty followed by calcium phosphate cement augmentation to prevent recurrent kyphosis. SUMMARY OF BACKGROUND DATA Failure after short-segment pedicle-screw fixation for the treatment of vertebral fractures is p...

متن کامل

Cement leakage into the posterior spinal canal during balloon kyphoplasty: a case report.

We report a case of cement leakage into the posterior spinal canal due to inadvertent pedicle perforation during balloon kyphoplasty. The leakage was corrected immediately without any sequelae. Features seen on radiography and the minimally invasive procedure used for removal are described. The postoperative radiographs of 100 consecutive patients treated with balloon kyphoplasty were subsequen...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2014