Left ventricular long-axis changes in early diastole and systole: impact of systolic function on diastole.

نویسندگان

  • Gabriel W Yip
  • Yan Zhang
  • Peggy Y Tan
  • Mei Wang
  • Pik-Yuk Ho
  • L-A Brodin
  • John E Sanderson
چکیده

Impaired long-axis motion is a sensitive marker of systolic myocardial dysfunction, but no data are available that relate long-axis changes in systole with those in diastole, particularly in subjects with diastolic dysfunction and a 'normal' left ventricular (LV) ejection fraction. A total of 311 subjects (including 105 normal healthy volunteers) aged 20-89 years with variable degrees of systolic function (LV ejection fraction range 0.15-0.84) and diastolic function were studied using tissue Doppler echocardiography and M-mode echocardiography to determine mean mitral annular amplitude and peak velocity in systole and early and late diastole. The LV systolic mitral annular amplitude (S(LAX), where LAX is long-axis amplitude) and peak velocity (S(m)) correlated well with the respective early diastolic components (E(LAX) and E(m)) and late diastolic (atrial) components (A(LAX) and A(m)). A non-linear equation fitted better than a linear relationship (non-linear model: S(LAX) against E(LAX), r(2)=0.67; S(m) against E(m), r(2)=0.60; S(LAX) against A(LAX) and S(m) against A(m), r(2)=0.42). After adjusting for age, sex and heart rate, linear relationships of early diastolic (E(LAX), r(2)=0.70; E(m), r(2)=0.60) and late diastolic (A(LAX), r(2)=0.61; A(m), r(2)=0.64) long-axis amplitudes and velocities with the respective values for S(LAX) and S(m) were found, even in those subjects with apparently 'isolated' diastolic dysfunction. Long-axis changes in systole or diastole did not correlate with Doppler mitral velocities. We conclude that ventricular long-axis changes in early diastole are closely related to systolic function, even in subjects with diastolic dysfunction. 'Pure' or isolated diastolic dysfunction is uncommon.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Cardiac Function in Young Patients with Thalassemia Intermedia and Healthy Individuals Using Echocardiography Method

Background: Cardiac dysfunction due to chronic anemia and hemosiderosis are the major causes of death among patients with thalassemia intermedia. This study was performed to compare the cardiac function in thalassemia intermedia patients with normal subjects by means of echocardiography. Materials and Methods: This was a case-control study performed on 22 patients affected by thalassemia int...

متن کامل

Quantification of and correction for left ventricular systolic long-axis shortening by magnetic resonance tissue tagging and slice isolation.

BACKGROUND Measurement of regional left ventricular (LV) function is predicted on the ability to compare equivalent LV segments at different time points during the cardiac cycle. Standard techniques of short-axis acquisition in two-dimensional echocardiography, cine computed tomography, and standard magnetic resonance imaging (MRI) acquire images from a fixed plane and fail to compensate for th...

متن کامل

Are changes in left ventricular volume as measured with the biplane Simpson's method predominantly related to changes in its area or long axis in the prognostic evaluation of remodelling following a myocardial infarction?

AIMS Two-dimensional (2D) echocardiography has been widely applied to measure left ventricular volumes with the biplane Simpson's method in the assessment of left ventricular remodelling following an acute myocardial infarction. This volume formula is based upon tracings of endocardium and measurement of long axis on left ventricular images. In the present follow-up study of post-myocardial inf...

متن کامل

CARDIOVASCULAR MEDICINE Left ventricular long axis function in diastolic heart failure is reduced in both diastole and systole: time for a redefinition?

Objective: To test the hypothesis that, when measured in the long axis, left ventricular systolic function is abnormal in patients with diastolic heart failure. Design: A case–control study. Setting: University teaching hospital (tertiary referral centre). Patients: 68 patients with heart failure, 29 with a left ventricular ejection fraction (LVEF) of > 0.45 and diastolic dysfunction (diastolic...

متن کامل

Left ventricular long axis function in diastolic heart failure is reduced in both diastole and systole: time for a redefinition?

OBJECTIVE To test the hypothesis that, when measured in the long axis, left ventricular systolic function is abnormal in patients with diastolic heart failure. DESIGN A case-control study. SETTING University teaching hospital (tertiary referral centre). PATIENTS 68 patients with heart failure, 29 with a left ventricular ejection fraction (LVEF) of > 0.45 and diastolic dysfunction (diastol...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical science

دوره 102 5  شماره 

صفحات  -

تاریخ انتشار 2002