Effect of Misalignment between Successive Corneal Videokeratography Maps on the Repeatability of Topography Data.

نویسندگان

  • FangJun Bao
  • JunJie Wang
  • JinHai Huang
  • Ye Yu
  • ManLi Deng
  • LinNa Li
  • Ayong Yu
  • QinMei Wang
  • Pinakin Gunvant Davey
  • Ahmed Elsheikh
چکیده

PURPOSE To improve the reliability of corneal topographic data through the development of a method to estimate the magnitude of misalignment between successive corneal videokeratography (VK) maps and eliminate the effect of misalignment on the repeatability of topography data. METHODS Anterior and posterior topography maps were recorded twice for 124 healthy eyes of 124 participants using a Pentacam, and the repeatability of measurements was assessed by calculating the differences in elevation between each two sets of data. The repeatability of measurements was re-assessed following the determination of the magnitude of misalignment components (translational displacements: x0, y0 and z0, and rotational displacements: α, β and γ) between each two data sets and using them to modify the second data set within each pair based on an Iterative Closest Point (ICP) algorithm. The method simultaneously considered the anterior and posterior maps taken for the same eye since they were assumed to have the same set of misalignment components. A new parameter, named Combined Misalignment parameter (CM), has been developed to combine the effect of all six misalignment components on topography data and so enable study of the association between misalignment and the data repeatability test results. RESULTS The repeatability tests resulted in average root mean square (RMS) differences in elevation data of 8.46±2.75 μm before ICP map matching when simultaneously considering anterior and posterior surfaces. With map matching and misalignment correction, the differences decreased to 7.28±2.58 μm (P = 0.00). When applied to only the anterior maps, misalignment correction led to a more pronounced reduction in elevation data differences from 4.58±1.84 μm to 2.97±1.29 μm (P = 0.00). CM was found to be associated with the repeatability error (P = 0.00), with posterior maps being responsible for most of the error due to their relatively lower accuracy compared to anterior maps. CONCLUSIONS The ICP algorithm can be used to estimate, and effectively correct for, the potential misalignment between successive corneal videokeratography maps.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Neural network classification of corneal topography. Preliminary demonstration.

PURPOSE Videokeratography is a powerful tool for the diagnosis of corneal shape abnormalities. However, interpretation of the topographic map is sometimes difficult, especially when pathologies with similar topographic patterns are suspected. The neural networks model, an artificial intelligence approach, was applied for automated pattern interpretation in corneal topography, and its usefulness...

متن کامل

Repeatability of corneal first-surface wavefront aberrations measured with Pentacam corneal topography.

PURPOSE To assess the repeatability of corneal wavefront aberrations derived from Pentacam (Oculus) corneal topography. SETTING Flinders Eye Centre, Flinders Medical Centre, Bedford Park, South Australia, Australia. METHODS Forty-five normal participants and 10 participants with keratoconus were tested. Intraobserver and interobserver repeatability was determined using 4 observers within an...

متن کامل

Validation of the estimation of corneal aberrations from videokeratography in keratoconus.

PURPOSE To validate the estimation of corneal aberrations from videokeratography against a laser ray tracing technique that measured total eye aberrations, in eyes without keratoconus (ie, cornea-dominated wave aberrations). METHODS We measured total and corneal wave aberrations of three eyes diagnosed with keratoconus by slit-lamp microscopy and corneal topography: two eyes from one patient ...

متن کامل

Repeatability and concordance of the Pentacam system. Comparative study of corneal parameters measured with Pentacam and Atlas Repetibilidad y concordancia de un sistema Pentacam. Comparación de parámetros corneales medidos con Pentacam y con Atlas

REFERENCES AND LINKS [1] W. N. Charman, “The retinal image in the human eye”, in Progress in Retinal Research, Pergamon, Oxford (1983). [2] A. A. Atchison, G. Smith, Optics of the Human Eye, Butterworth-Heinnemann, Oxford (2000). [3] P. Artal, A. Guirao, “Contribution of corneal and lens to the aberrations of the human eye”, Opt. Lett. 23, 1713-1715 (1998). [4] A. Guirao, P. Artal, “Corneal wav...

متن کامل

بررسی اثر قطره هوماتروپین 2% بر روی توپوگرافی قرنیه

 ABSTRACT The purpose of this study was the evaluation of cycloplegic effect of homatropine 2% on central corneal curvature and power. 43 volunteers who participated in the study were examined. Thirty-nine of them (28 men and 11 women) which had normal eyes with visual acuity of 20/20 and a mean age of 29.6 ± 6.7 years were selected. Then corneal topography was performed on both eyes. After per...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • PloS one

دوره 10 11  شماره 

صفحات  -

تاریخ انتشار 2015