The recent developments of new devices and advances in anesthesiology have greatly improved the utility and accuracy of intraoperative neurophysiological monitoring (IOM). Herein, we review the basic principles of the electrophysiological methods employed under IOM in the operating room. These include motor evoked potentials, somatosensory evoked potentials, electroencephalography, electromyography, brainstem auditory evoked potentials, and visual evoked potentials. Most of these techniques have certain limitations and their utility is still being debated. In this review, we also discuss the optimal stimulation/recording method for each of these modalities during individual surgeries as well as the diverse criteria for alarm signs.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

National competencies for performing intraoperative neurophysiologic monitoring.

Basic knowledge and technical performance, as well as quality patient care and patient interaction, were considered. The technical components include those defined in the publication Guidelines in EEG, Evoked Potentials and Polysomnography 1994 authored by the American Clinical Neurophysiology Society; Intraoperative EEG Guidelines authored by ASET; and a draft document, Practice Guidelines, by...

متن کامل

Herniated lumbar disc surgery in triathlon athletes with intraoperative neurophysiologic monitoring Cirurgia de hérnia de disco lombar em atleta de triathlon com monitoração neurofisiológica intraoperatória

Intraoperative neurophysiologic monitoring was performed in a patient by somatosensory evoked potential, motor evoked potential and free-running electromyography with intraoperative stimulation. It was verified that after decompression, there was an increase in the amplitude of motor evoked potential responses, showing an immediate improvement of the treated levels. Intraoperative neurophysiolo...

متن کامل

Potential neurological risk during a titanium rib procedure and appropriate intraoperative neurophysiologic monitoring modalities.

The titanium rib procedure is a safe and effective way of surgically treating pediatric patients with thoracic insufficiency syndrome and scoliosis. As with any invasive surgical procedure, it is not without risks. This article explains the potential risks to neurological structures while outlining the surgical approach and the neurological anatomy in the vicinity of the implanted instrumentati...

متن کامل

Intraoperative neurophysiologic monitoring during spinal surgery.

Intraoperative neurophysiologic monitoring (IONM) is a battery of neurophysiologic tests used to assess the functional integrity of the spinal cord, nerve roots, and other peripheral nervous system structures (eg, brachial plexus) during spinal surgery. The underlying principle of IONM is to identify emerging insult to nervous system structures, pathways, and/or related vascular supply and to p...

متن کامل

Anesthesia for intraoperative neurophysiologic monitoring of the spinal cord.

Intraoperative neurophysiologic monitoring (INM) using somatosensory and motor evoked potentials (MEPs) has become popular to reduce neural risk and to improve intraoperative surgical decision making. Intraoperative neurophysiologic monitoring is affected by the choice and management of the anesthetic agents chosen. Because inhalational and intravenous anesthetic agents have effects on neural s...