Comparison of pupil diameter measurement with Lenstar LS 900 and OPD Scan II. Not interchangeable devices.
نویسندگان
چکیده
D pupil measurement is of great concern in corneal refractive surgery, as well as when phakic or multifocal intraocular lens (IOL) implantation is planned.1,2 Pupil size may influence the choice of ablation zone in refractive surgery and IOL design in cataract surgery, and it should be measured accurately so as not to end up with unfavorable postoperative outcomes, such as halos, glare, or poor night vision. Although several types of devices, such as infrared pupillometers and infrared photography methods, are available for measurement of pupil diameter, in clinical practice, surgeons may prefer the use of one device for measurement of many parameters related to the cornea or the anterior segment of the eye.3-5 The OPD Scan II (Nidek, Osaka, Japan) is a corneal aberrometrytopography (CAT) device that can simultaneously evaluate corneal topography, high order aberrations, and mesopic and scotopic pupil diameter measurement. The Lenstar LS 900 II (Haag Streit, Koeniz, Switzerland) is a low coherence optical reflectometer that is capable of measuring anterior segment parameters, including corneal thickness, anterior chamber depth, lens thickness, and white-to-white distance, as well as pupil diameter. The objective of this study was to compare the capability of optical low coherence reflectometry (OLCR) and CAT to measure pupil diameter, and to evaluate their correlation in the assessment of cataract and refractive surgery. This comparative, observational study, conducted in the Department of Ophthalmology, Faculty of Medicine, Selcuk University, Konya, Turkey, between July and August 2011, adhered to the tenets of the Declaration of Helsinki, and the local ethics committee approved the study protocol. All patients gave their informed consent for the study. Seventy-two eyes (one randomly selected eye) of 72 emmetropic patients were recruited for this study. Inclusion criterion included no history of systemic or ocular disease. A complete ophthalmic examination was performed on every participant, and any history of ocular trauma, surgery, or usage of topical eye drops composed the exclusion criteria. All the measurements were performed in mesopic room conditions (2 lux illumination (measured with International Light IL 1700 Radiometer, Newburyport, MA, USA), and with native pupils. For dark adaptation, the subjects wore dark wrapped cataract glasses for 5 minutes. After dark adaptation, the pupil diameter was measured with a topography-aberrometer (OPD Scan II, Nidek, Osaka, Japan), and low coherence optical reflectometry (Lenstar LS 900, Haag-Streit, Koeniz, Switzerland) in random order. The time interval between the 2 measurements was 15 minutes; the same experienced examiner performed the measurements. All the measurements were taken between 3 and 4 p.m. Independent t-test using the Statistical Package for Social Sciences version 16.0 (SPSS Inc., Chicago, IL, USA) was used for statistical analysis. A p-value less than 0.05 was taken as statistically significant. Intraclass correlation and Spearman’s coefficients were calculated. The mean age of the 72 patients (38 female, 34 male) was 26.2±8.1 years (range 19-43 years). The mean results of pupil size measured with OPD under photopic conditions were 4.31±0.49 mm (range 314-5.42), and under mesopic conditions were 6.26±0.61 mm (range 4.74-7.76), while the mean results of pupil size measured with OLCR in mesopic conditions were 5.82±0.99 mm (range 3.20-8.97). Statistically significant differences were observed in the results of the photopic and mesopic conditions with OPD (p=0.001). The OPD measured the mesopic pupil diameter 0.44 mm larger than the Lenstar did; this difference was statistically significant (p=0.001). The intraclass correlation coefficient for mesopic pupil diameter measurements with OPD and Lenstar was 48.59% (95% confidence interval: 28.78%–64.41%). Spearman’s correlation coefficient was r=0.54. The preoperative evaluation of patients is as important as the surgery itself in refractive procedures, including corneal refractive surgery, phakic IOL implantation, and multifocal IOL implantation.1,2 The ablation zone is the area of the cornea that includes the fully corrected optical ablation zone and the transition zone. It is adjusted for mesopic pupil diameter, as the dark-adapted pupil diameter can influence the choice of ablation optical zone diameter. In the planning of multifocal IOL implantation, dark-adapted pupil diameter should have been measured objectively to determine the IOL design. Brief Communication
منابع مشابه
Axial Length Measurement Failure Rates with the IOLMaster and Lenstar LS 900 in Eyes with Cataract
PURPOSE To evaluate axial length (AL) measurement failure rate with the IOLMaster (Carl Zeiss AG, Germany) and Lenstar LS 900 (Haag-Streit AG, Switzerland) in eyes with cataract. METHODS Two hundred and ninety-six eyes of 170 patients with cataract were enrolled. Cataract type and severity were graded using the Lens Opacities Classification System III (LOCS III) and AL measurements were attem...
متن کاملComparison of measurement of pupil sizes among the colvard pupillometer, procyon pupillometer, and NIDEK OPD-scan.
PURPOSE To compare pupil sizes measured with the Colvard pupillometer, Procyon pupillometer, and NIDEK OPD-Scan. METHODS Pupil diameter was measured in 90 consecutive eyes from 55 patients under mesopic and scotopic light conditions with all three instruments. RESULTS The mean scotopic pupil diameter was 6.3+/-0.98 mm with the Colvard pupillometer and 6.45+/-1.01 mm with the Procyon pupillo...
متن کاملComparison of Internal and Total Optical Aberrations for 2 Aberrometers: iTrace and OPD Scan
PURPOSE To compare and evaluate the total and internal aberrations measured by two aberrometers: the laser ray tracing aberrometer (iTrace, Tracey Technology) and the automatic retinoscope aberrometer (OPD Scan, Nidek). METHODS A total of 54 healthy eyes were enrolled in the study. Following pupil dilation, aberrations were measured with the iTrace and OPD Scan. We compared the aberrations ob...
متن کاملComparison of corneal power obtained from VERION image-guided surgery system and four other devices
PURPOSE To assess the corneal keratometric values obtained using the VERION image-guided surgery system and other devices. METHODS This study evaluated the right eyes of 115 cataract patients before intraocular lens (IOL) implantation through consecutive tests using 5 devices: VERION Reference Unit, Placido-based corneal topography (OPD-Scan III), monochromatic light-emitting diodes (LenStar ...
متن کاملAcuTarget measurements: repeatability and comparison to OPD-Scan III.
PURPOSE To evaluate repeatability of the AcuTarget (SensoMotoric Instruments, Teltow, Germany) measurements and compare them to those obtained with the OPD-Scan III (NIDEK, Inc., Fremont, CA). METHODS Measurements were taken with the AcuTarget and OPD-Scan III in 62 eyes of 31 patients. Results were compared using paired Student's t tests, Pearson correlation coefficients, and 95% limits of a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Saudi medical journal
دوره 33 11 شماره
صفحات -
تاریخ انتشار 2012