On the Implementation of the IEC 61850 Standard: Will Different Manufacturer Devices Behave Similarly under Identical Conditions?
نویسندگان
چکیده
Standardization in smart grid communications is necessary to facilitate complex operations of modern power system functions. However, the strong coupling between the cyber and physical domains of the contemporary grid exposes the system to vulnerabilities and thus places more burden on standards’ developers. As such, standards need to be continuously assessed for reliability and are expected to be implemented properly on field devices. However, the actual implementation of common standards varies between vendors, which may lead to different behaviors of the devices even if present under similar conditions. The work in this paper tested the implementation of the International Electro-technical Commission’s Generic Object Oriented Substation Event GOOSE (IEC 61850 GOOSE) messaging protocol on commercial Intelligent Electronic Devices (IEDs) and the open source libiec61850 library—also used in commercial devices—which showed different behaviors in identical situations. Based on the test results and analysis of some features of the IEC 61850 GOOSE protocol itself, this paper proposes guidelines and recommendations for proper implementation of the standard functionalities.
منابع مشابه
Comparative Reliability Analysis of Substation Automation Architecture Based on IEC 61850 Standard
Using IEC 61850 standard would increase the reliability and availability of electricity network and put a huge impact on network automation. Even though much research works has been done in substation system reliability, there is a few works in automated substation control system reliability. This paper evaluates the reliability of substation automation system based IEC 61850 comparatively cons...
متن کاملWireless Light-Weight IEC 61850 Based Loss of Mains Protection for Smart Grid
This paper presents a novel Loss of Mains (LoM) protection method based on IEC 61850 Manufacturing Messages Specification (MMS) protocol over wireless Global System for Mobile Communication (GSM) based access point name (APN) mechanism. LoM or anti-islanding protection is a key requirement in modern power distribution grids where there is significant amount of distributed energy resources (DER)...
متن کاملReal Time Simulation Testing Using IEC 61850
-As IEC 61850 becomes more widely accepted in the electrical engineering community, it is important that the testing tools keep pace with this development. IEC 61850 presents new challenges to real time simulation and closed-loop testing of protective relays. Electrical interfaces used for binary signaling and voltage/current amplifiers must be replaced by an Ethernet connection and an IEC 6185...
متن کاملModeling interoperable protection and control devices for substation automation according to IEC 61850
according to IEC 61850 Klaus-Peter Brand, Wolfgang Wimmer Switzerland Summary The standard IEC 61850 „Communication Networks and Systems in Substations“ will provide interoperability for all functions in substations. To realize interoperable devices their data and functions have to be modeled according to IEC 61850. The approach and the data model of the standard is the key for understanding, b...
متن کاملT Implementation Issues with IEC 61850 Based Substation Automation Systems
International Electro-technical Commission (IEC) has developed a new global standard, IEC 61850 for communication systems in power substations. This standard provides interoperability among the all communication devices within the substation. This paper presents basic features of communication systems proposed by IEC 61850, such as functional hierarchy, OSI-7 layer based communication, and proc...
متن کامل