HTAC: An atomic multiplet code for the calculation of various atomic properties

نویسندگان

  • Safeia Hamasha
  • Amani Naser Tahat
چکیده

We describe an atomic multiplet code (HTAC) for the calculation of various atomic radiative processes, including energy levels, oscillator strength, radiative transition rates, mixing coefficients for any rank of mutipole transitions, and other quantities.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Gamma-ray shielding properties for silicate glasses containing Bi2O3, PbO, and BaO

Introduction: With the extensive application of radiation sources and radioactive materials in various fields, the study of attenuation and absorption of X-rays and gamma-rays in several materials has become an essential and interesting field of research. Glass materials are possible alternatives of concretes for radiation-shielding materials.   Materials and Methods:...

متن کامل

Monte Carlo calculation of shielding properties of newly developed heavy concretes for megavoltage photon beam spectra used in radiation therapy

Introduction: Globally, the need for radiotherapy as a part of cancer management increases every year. Thus, the shielding for megavoltage radiotherapy rooms is of great importance. Materials and Methods: In the present study, 14 types of developed high-density concrete with densities ranging from 2.45 to 5.11 were simulated by using Monte Carlo method. The linear attenuation coefficient and t...

متن کامل

An Ab initio and chemical shielding tensors calculations for Nucleotide 5’-Monophosphates in the Gas phase

Structural and magnetic properties of purine and pyrimidine nucleotides (CMP, UMP, dTMP, AMP, GMP, IMP) were studied at different levels of ab initio molecular orbital theory. These calculations were performed at the hartree-fock level and density functional B3LYP methods. Geometries were fully optimized by following Cs symmetry restrictions. The standard 6-31G** basis set which includes polari...

متن کامل

Estimation of neutron and gamma dose in the MNSR research reactor

In this study, the neutron and gamma doses in the dry channel and in the internal irradiation site of the Miniature Neutron Source research reactor (MNSR) has been calculated and measured. The MNSR reactor is a light water reactor with a maximum power of 30 kW and equipped with various irradiation facilities, including five irradiated sites, five irradiation sites and a dry channel. The interna...

متن کامل

A study of opacity in SOHO-SUMER and SOHO-CDS spectral observations I. Opacity deduction at the limb

A study is presented of the optical thickness of spectral lines of carbon, nitrogen and oxygen ions in the quiet sun. The observations consist of cross limb scans by the SUMER and CDS spectrometers on the SOHO spacecraft. A maximum likelihood spectral line fitting code has been adapted to analyse the multiplet profiles and to provide an assessment of errors in the count rates, especially of clo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010