Resistive wall impedance and tune shift for a chamber with a finite thickness.

نویسندگان

  • Yoshihiro Shobuda
  • Kaoru Yokoya
چکیده

Since the resistive wall impedance for a beam pipe of a nonround cross section depends on the coordinates of a witness particle, the witness particle receives an incoherent tune shift. When the expression for the impedance of an infinitely thick chamber is applied to the calculation of this tune shift, it becomes infinite. We have derived the resistive wall impedance for a chamber with a finite thickness and calculated the tune shift. There is no ambiguity in this expression for the tune shift, because it is automatically finite.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

EUROPEAN ORGANIZATION FOR NUCLEAR RESEARCH AB-Note-2006-007 ABP Coherent and Incoherent Tune Shift Induced by the Nonlinear Flat-Chamber Resistive-Wall Wake Field with an Application to the LHC Collimator Experiment in the SPS

We derive formulae for the coherent and incoherent tune shift due to the nonlinear resistive-wall wake field for a single beam travelling between two parallel plates. The theoretical predictions are compared with measurements performed on an LHC prototype collimator during the 2004 SPS run. We show that the tune shift derived from the nonlinear wake field yields a better agreement with the meas...

متن کامل

Horizontal Instability in the KEKB HER

After a brief introduction to the problem, I study several aspects related to the horizontal instability in the KEKB HER, namely resistive-wall instability, ion trapping and ion instability, ion losses and the associated modification of the fast beam-ion instability, measurements of coupledbunch oscillations and their simulation assuming they are driven by ions, resistive wall, or electron clou...

متن کامل

Analysis of Transverse Resistive Instability in the Recycler

Transverse resistive wall instability is analysed for antiprotons in the Recycler Ring. Damper requirements are formulated. 1 Growth Rate and Landau Damping 1.1 Coasting Beam Coherent instabilities are driven by the real part of impedance. For a coasting beam with insigni…cant frequency spread, the impedance-driven coherent tune shift at the harmonic number n is given by (see e. g. [1]) Z !Z=!0...

متن کامل

How Many IVUs Can We Install without Sacrificing 16-mA Operation?

Let’s define the vertical impedance of an 8-mm gap chamber due to geometric variation as one unit of impedance with the symbol zu. Since the resistive wall impedance of an 8mm gap chamber is 0.3 zu [2], the total impedance of an 8-mm gap chamber is 1.3 zu. The geometric impedance of a 5-mm gap chamber is 3.09 zu, which we obtained using the known scaling in Eq. (1) derived in [1]. Including 1.2...

متن کامل

The evaluation of minimum detectable phantom thickness change using a scanning liquid filled ion chamber EPID dose response

 ABSTRACTBackground: Although Electronic Portal imaging Devices (EPIDs) have originally developed for positioning verification, they can also be used for dosimetric purposes. In the current work, the dose response of minimum detectable thickness of a Scanning Liquid filled Ion Chamber EPID, SLIC-EPID, and the variation of transmitted dose with the shift of inhomogeneity inside of phantom was al...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physical review. E, Statistical, nonlinear, and soft matter physics

دوره 66 5 Pt 2  شماره 

صفحات  -

تاریخ انتشار 2002