Standard Enucleation with Aluminium Oxide Implant (Bioceramic) Covered with Patient's Sclera

نویسندگان

  • Gian Luigi Zigiotti
  • Sonia Cavarretta
  • Mariachiara Morara
  • Sang Min Nam
  • Stefano Ranno
  • Francesco Pichi
  • Andrea Lembo
  • Stefano Lupo
  • Paolo Nucci
  • Alessandro Meduri
چکیده

PURPOSE We describe in our study a modified standard enucleation, using sclera harvested from the enucleated eye to cover the prosthesis in order to insert a large porous implant and to reduce postoperative complication rates in a phthisis globe. METHODS We perform initially a standard enucleation. The porous implant (Bioceramic) is then covered only partially by the patient's sclera. The implant is inserted in the posterior Tenon's space with the scleral covering looking at front. All patients were followed at least for twelve months (average followup 16 months). RESULTS We performed nineteen primary procedures (19 patients, 19 eyes, x M; x F) and secondary, to fill the orbital cavity in patients already operated by standard evisceration (7 patients, 7 eyes). There were no cases of implant extrusion. The orbital volume was well reintegrated. CONCLUSION Our procedure was safe and effective. All patients had a good cosmetic result after final prosthetic fitting and we also achieved good prothesis mobility.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

ENUCLEATION IN MALIGNANT CHOROIDAL MELANOMA - results in 15 years of using a new material in the prosthesis of the orbital cavity

RATIONALE Enucleation implants are covered with a material that allows the fixation of the extraocular rectus muscles. Usually, the implants are covered in donor sclera, which implies the risk of infection transmission, inflammation and implant rejection, being also an expensive procedure. The new materials used for implant meshing should be tested and a safer and cost effective solution should...

متن کامل

Comparative study of modified and conventional secondary hydroxyapatite orbital implantations.

AIM To compare the clinical effects of the modified and conventional secondary hydroxyapatite orbital implantations. METHODS A total of 40 patients who had received eye enucleation were equally randomized into the modified and conventional groups. Twenty patients were treated by conventional method. The four rectus muscles were separated, and then an orbital implant wrapped with xenogenous sc...

متن کامل

CLINICAL SCIENCE Long term follow up of bone derived hydroxyapatite orbital implants

Aims: To document the long term experience of bone derived hydroxyapatite orbital implants and compare results using scleral wrapped implants with those not using sclera. Methods: This retrospective case series reviewed the long term follow up of 118 patients with 120 eyes which had undergone enucleation and bone derived hydroxyapatite orbital implant insertion at Dunedin Hospital from 1977 unt...

متن کامل

Long term follow up of bone derived hydroxyapatite orbital implants.

AIMS To document the long term experience of bone derived hydroxyapatite orbital implants and compare results using scleral wrapped implants with those not using sclera. METHODS This retrospective case series reviewed the long term follow up of 118 patients with 120 eyes which had undergone enucleation and bone derived hydroxyapatite orbital implant insertion at Dunedin Hospital from 1977 unt...

متن کامل

Long-term Surgical Outcomes of the Multi-purpose Conical Porous Synthetic Orbital Implant

PURPOSE We present clinical results of the use of the multipurpose conical porous synthetic orbital implant (MCOI) in surgical procedures of evisceration, enucleation, and secondary enucleation in ophthalmology patients. METHODS A retrospective review was performed of 59 eyes in which conical implants were used, including 36 cases of eviscerations, 11 enucleations, and 9 secondary enucleation...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2012  شماره 

صفحات  -

تاریخ انتشار 2012