Fast spin-echo MR in hippocampal sclerosis: correlation with pathology and surgery.
نویسندگان
چکیده
PURPOSE To identify the extent of hippocampal sclerosis in temporal lobe epilepsy with fast spin-echo MR and correlate it with histopathologic findings and surgical outcome. METHODS MR images of 30 patients with temporal lobe epilepsy and pathologically proved hippocampal sclerosis and 30 control subjects were obtained using a fast spin-echo technique with 4000/100/4 (repetition time/echo time/excitations), 16 echo train, 2- to 3-mm section thickness with interleave, 256 x 256 matrix, and 18-cm field of view. Criteria for MR diagnosis of hippocampal sclerosis included hippocampal atrophy diagnosed with MR volumetry and/or T2-weighted signal change. Hippocampal sectional areas were plotted, and T2 signal changes were topographically evaluated to identify the extent of hippocampal sclerosis, which was subsequently correlated with histopathologic findings and surgical outcome. RESULTS Hippocampal sclerosis was diffuse, involving both hippocampal head and body, in 96.7% of patients (29 of 30 patients). One patient had normal MR findings. Focal hippocampal sclerosis was not seen. Histopathologic findings of hippocampal sclerosis were present in all 29 patients who had abnormal MR findings. Eighty-six percent of patients (18 of 21 patients), who were followed for at least 1 year after temporal lobectomy, were seizure free (81%, 17 of 21 patients) or significantly improved (5%, 1 of 21 patients). CONCLUSION Fast spin-echo MR enables accurate definition of the extent of hippocampal sclerosis in patients with temporal lobe epilepsy. All cases of hippocampal sclerosis identified in this study involved the hippocampus diffusely. However, leaving the posterior portion of the hippocampus during surgery does not seem to be a major factor influencing surgical outcome.
منابع مشابه
Comparison of MR pulse sequences in the detection of multiple sclerosis lesions.
PURPOSE To compare the sensitivity of conventional spin-echo, fast spin-echo, fast fluid-attenuated inversion recovery (FLAIR), and turbo gradient spin-echo MR sequences in the detection of multiple sclerosis lesions. METHODS Conventional spin-echo, fast spin-echo, fast FLAIR, and turbo gradient spin-echo sequences were performed on a 1.0-T MR imager in seven patients with clinically definite...
متن کاملHippocampal Sclerosis: Correlation of MR Imaging Findings with Surgical Outcome
OBJECTIVE Atrophy and a high T2 signal of the hippocampus are known to be the principal MR imaging findings of hippocampal sclerosis. The purpose of this study was to determine whether or not individual MRI findings correlate with surgical outcome in patients with this condition. MATERIALS AND METHODS Preoperative MR imaging findings in 57 consecutive patients with pathologically-proven hippo...
متن کاملProton Density MRI Increases Detection of Cervical Spinal Cord Multiple Sclerosis Lesions Compared with T2-Weighted Fast Spin-Echo.
BACKGROUND AND PURPOSE There is a paucity of literature that supports the Consortium of Multiple Sclerosis Centers guideline that proton density MR imaging is a core spinal cord sequence. We hypothesized that proton density fast spin-echo imaging is superior to T2 fast spin-echo MR imaging for the detection of cervical cord MS lesions. This study compared the detection rate and conspicuity of c...
متن کاملT2 relaxometry of the hippocampus at 3T.
BACKGROUND AND PURPOSE T2 mapping is useful for identifying and quantifying abnormalities of the hippocampus and amygdala. It is particularly useful in the presurgical evaluation of patients with temporal lobe epilepsy and for the identification of bilateral hippocampal sclerosis (HS). The purpose of this study was to implement and validate a dual-echo method for producing coronal T2 maps with ...
متن کاملComparison the Accuracy of Fetal Brain Extraction from T2-Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (HASTE) MR Image with T2-True Fast Imaging with Steady State Free Precession (TRUFI) MR Image by Level Set Algorithm
Background Access to appropriate images of fetal brain can greatly assist to diagnose of probable abnormalities. The aim of this study was to compare the suitability of T2-True Fast Imaging with Steady State Free Precession (T2-TRUFI), and T2-Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (T2- HASTE( magnetic resonance imaging (MRI) to extract the fetal brain using the level set algorithm...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 16 4 شماره
صفحات -
تاریخ انتشار 1995