Resolution comparison between integral-imaging-based hologram synthesis methods using rectangular and hexagonal lens arrays.

نویسندگان

  • Ni Chen
  • Jiwoon Yeom
  • Jae-Hyun Jung
  • Jae-Hyeung Park
  • Byoungho Lee
چکیده

We compare the resolution of the hologram reconstruction synthesis methods based on integral imaging using rectangular and hexagonal lens arrays. By using a hexagonal lens array instead of conventional rectangular lens array, the three-dimensional objects are sampled with hexagonal grids. Due to more efficient sampling of the hexagonal grid, the resolution of the reconstructed object is higher compared with the case of using rectangular lens array. We analyze the resolution enhancement of the hologram reconstruction quantitatively and verify it experimentally.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Homogeneous LED-illumination using microlens arrays

Efficient homogeneous illumination of rectangular or circular areas with LEDs is a promising application for doublesided microlens arrays. Such illumination schemes employ a primary optics which can be realized with a concentrator or a collimation lens and a secondary optics with one or more double-sided microlens arrays and a collection optics for superposing the light from the individual arra...

متن کامل

Adaptive beamforming in row-column addressed arrays for 3D ultrasound imaging

In recent years, to reduce the complexity of implementation, the use of 2D arrays with restricted row-column addressing has been considered for 3D ultrasound imaging. In this paper, two methods of adaptive beamforming based on the minimum variance method are represented in such a way that the computational load is much less than using the full adaptive beamforming method. In both proposed metho...

متن کامل

Optimization of an ultra-high-resolution rectangular pixelated parallel-hole collimator with a CZT pixelated semiconductor detector for HiRe-SPECT system

Introduction: In nuclear medicine, the use of a pixelated semiconductor detector such as CZT is an of growing interest for introducing new devices. Especially, the spatial resolution can be improved by using a pixelated parallel-hole collimator with equal holes and pixel sizes based on the pixelated detector. The purpose of this study was to compare the effect of pixelated and ...

متن کامل

3D capturing devices based on the principles of Integral Photography

In this article novel approaches for capturing 3D scenes are presented based on the technique of Integral Photography. The novelty in our method includes the development of robust, low complexity and high accuracy capturing devices using a depth control lens for managing the reconstruction of the 3D scene in front or behind the surface of the display device. To this end, high-resolution CCD sen...

متن کامل

The processing of hexagonally sampled signals with standard rectangular techniques: application to 2-D large aperture synthesis interferometric radiometers

In Earth observation programs there is a need of passive low frequency (L-band) measurements to monitor soil moisture and ocean salinity with high spatial resolution 10–20 Km, a radiometric resolution of 1K and a revisit time of 1–3 days [1]. Compared to total power radiometers aperture synthesis interferometric radiometers are technologically attractive because of their reduced mass and hardwa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Optics express

دوره 19 27  شماره 

صفحات  -

تاریخ انتشار 2011