High Risk HPV Contamination of Endocavity Vaginal Ultrasound Probes: An Underestimated Route of Nosocomial Infection?

نویسندگان

  • Jean-sebastien Casalegno
  • Karine Le Bail Carval
  • Daniel Eibach
  • Marie-Laure Valdeyron
  • Gery Lamblin
  • Hervé Jacquemoud
  • Georges Mellier
  • Bruno Lina
  • Pascal Gaucherand
  • Patrice Mathevet
  • Yahia Mekki
چکیده

BACKGROUND Endocavity ultrasound is seen as a harmless procedure and has become a common gynaecological procedure. However without correct disinfection, it may result in nosocomial transmission of genito-urinary pathogens, such as high-risk Human Papillomavirus (HR-HPV). We aimed to evaluate the currently recommended disinfection procedure for covered endocavity ultrasound probes, which consists of "Low Level Disinfection" (LLD) with "quaternary ammonium compounds" containing wipes. METHODS From May to October 2011 swabs were taken from endovaginal ultrasound probes at the Gynecology Department of the Lyon University Hospital. During the first phase (May-June 2011) samples were taken after the ultrasound examination and after the LLD procedure. In a second phase (July-October 2011) swab samples were collected just before the probe was used. All samples were tested for the presence of human DNA (as a marker for a possible transmission of infectious pathogens from the genital tract) and HPV DNA with the Genomica DNA microarray (35 different HPV genotypes). RESULTS We collected 217 samples before and 200 samples after the ultrasound examination. The PCR was inhibited in two cases. Human DNA was detected in 36 (18%) post-examination samples and 61 (28%) pre-examination samples. After the ultrasound LLD procedure, 6 (3.0%) samples contained HR-HPV types (16, 31, 2×53 and 58). Similarly, HPV was detected in 6 pre-examination samples (2.7%). Amongst these 4 (1.9%) contained HR-HPV (types 53 and 70). CONCLUSION Our study reveals that a considerable number of ultrasound probes are contaminated with human and HR-HPV DNA, despite LLD disinfection and probe cover. In all hospitals, where LLD is performed, the endovaginal ultrasound procedure must therefore be considered a source for nosocomial HR-HPV infections. We recommend the stringent use of high-level disinfectants, such as glutaraldehyde or hydrogen peroxide solutions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

UVC radiation as an effective disinfectant method to inactivate human papillomaviruses

Endocavitary ultrasound probes are part of a commonly used procedure in the clinical arena. The cavities examined, vaginal canal and cervix, anal canal, and oral cavity are all areas commonly infected with the human papillomavirus (HPV), thus making them susceptible to contamination by HPV. It has been demonstrated that these probes can remain contaminated with high-risk HPV even when approved ...

متن کامل

Bacterial contamination of ultrasound probes at a tertiary referral university medical center.

OBJECTIVE The purpose of this study was to assess the adequacy of our institution's ultrasound probe-disinfecting protocols, determine compliance with the guidelines, and then implement changes if needed. MATERIALS AND METHODS We first assessed the prevalence of bacterial contamination (and thus the potential for bacterial transmission) by swabbing all ultrasound probes (n = 31) in the radiol...

متن کامل

Role of ultrasound probes in transmission of hospital infections

Background: The ultrasonography probes are cleaned by absorbent soft, dry cloth. This question arose whether linear and convex ultrasound probes coupling with gel could perform as a means for nosocomial infections transmission, and which method is economical and more efficient for cleaning the probes. This study was conducted to answer these questions. Methods: One hundred – ninety two patients...

متن کامل

Impact of vaginal-rectal ultrasound examinations with covered and low-level disinfected transducers on infectious transmissions in france.

BACKGROUND The risk of cross-infection from shared ultrasound probes in endorectal and vaginal ultrasonography due to low-level disinfection (LLD) is difficult to estimate because potential infections are also sexually transmitted diseases, and route of contamination is often difficult to establish. In France, the widely used standard for prevention of infections is through the use of probe cov...

متن کامل

Hospital-wide survey of bacterial contamination of point-of-care ultrasound probes and coupling gel.

OBJECTIVES The purpose of this study was to determine the hospital-wide incidence of bacterial contamination of point-of-care (bedside) ultrasound probes and coupling gel at a single academic medical center to predict the risk of nosocomial spread of infection. METHODS Bacterial cultures were performed on all point-of-care ultrasound probe surfaces and associated gel bottles in our institutio...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2012