Comparative study on dosimetry of VMAT and IMRT in assisted radiotherapy after radical resection of rectal cancer

نویسندگان

  • Jianguo Shi
  • Fujun Yang
  • Xiangbai Ju
  • Yudong Huang
  • Fenge Jiang
چکیده

The present study compared the dosimetric differences of volumetric modulated arc therapy (VMAT) and 7-field intensity modulated radiation therapy technology (7F-IMRT) in assisted radiotherapy plan after resection of rectal carcinoma. Ten cases of patients at stages II-III of rectal cancer transabdominal resection with postoperative pelvic radiotherapy underwent 7F-IMRT and VMAT radiotherapy plan design using the CMS Monaco treatment planning system. We compared the dose distribution, the number of organs at risk and the number of machines in the two groups. The 7F-IMRT plans conformal index (CI) was 0.8319±0.0143 and VMAT plans CI was 0.838±0.164. Both plans reached up to the 95% isodose line at a volume of 100% planning target volume (PTV), the 7F- IMRT plans homogeneity index (HI) was 1.0760±0.0179, and the VMAT plans HI was 1.0821±0.0143. CI and HI had no statistical difference. With regard to S40, the V50 dose volume of the small intestine was endangered, and the VMAT plan was better than that of the 7F-IMRT plan, and the difference was statistically significant (P<0.05). The machine hop numbers of the two types of plans were 594.1±36.1 and 793.2 ±56.6 for for VMAT and 7F-IMRT, respectively. The VMAT plan was less than htat of the 7F-IMRT and the difference was statistically significant (P<0.05). Patients to whom VMAT techniques were utilized after resection of rectal cancer obtained an equal or a superior dose distribution compared with the IMRT plan. VMAT had important significance in protecting the small intestine, while significantly reducing treatment time.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimization of prostate cancer radiotherapy using of a spacer gel, volumetric modulated arc therapy and a single biological organ at risk objective

Background: The aim was to evaluate the benefit of technical advances for treatment planning: introduction of a hydrogel spacer, VMAT (volumetric modulated arc therapy) and a single biological organ at risk objective for the rectum and bladder. Initial standard was a step-and-shoot IMRT (intensity modulated radiotherapy) without a spacer and conventional organ at risk objectives.&nbsp; Material...

متن کامل

Dosimetric Evaluation of Volumetric Modulated Arc Therapy (VMAT) and Intensity Modulated Radiotherapy (IMRT) Using AAPM TG 119 Protocol

Background: The commissioning accuracy of Volumetric Modulated Arc Therapy (VMAT) need to be evaluated.Objective: To test and evaluate commissioning accuracy of VMAT based on the TG 119 protocols at local institution. Material and Methods: The phantom, structure sets, VMAT and IMRT beam parameter setup, dose prescriptions and planning objectives were following TG 119 guidelines to c...

متن کامل

Volumetric modulated arc therapy with simultaneous integrated boost for locally advanced rectal cancer.

AIMS To report the feasibility of volumetric modulated arc therapy (VMAT) for neoadjuvant radiotherapy in locally advanced rectal cancer in a dose-escalation protocol and simultaneous integrated boost (SIB) approach. Moreover, the VMAT technique was compared with three-dimensional conformal radiotherapy (3D-CRT) and fixed-field intensity modulated radiotherapy (IMRT), in terms of target coverag...

متن کامل

Dosimetric and radiobiological characterizations of prostate intensity-modulated radiotherapy and volumetric-modulated arc therapy: A single-institution review of ninety cases

This study reviewed prostate volumetric-modulated arc therapy (VMAT) plans with intensity-modulated radiotherapy (IMRT) plans after prostate IMRT technique was replaced by VMAT in an institution. Characterizations of dosimetry and radiobiological variation in prostate were determined based on treatment plans of 40 prostate IMRT patients (planning target volume = 77.8-335 cm(3)) and 50 VMAT pati...

متن کامل

Dosimetric comparisons of VMAT, IMRT and 3DCRT for locally advanced rectal cancer with simultaneous integrated boost

PURPOSE The purpose of this study is to compare the dosimetric differences among volumetric modulated arc therapy (VMAT), fixed-field intensity modulated radiotherapy (IMRT) and three-dimensional conformal radiotherapy (3D-CRT) for the preoperative locally advanced rectal cancer (LARC). METHODS Ten LARC patients treated in our department using the simultaneous escalate strategy were retrospec...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 13  شماره 

صفحات  -

تاریخ انتشار 2017