A comment on 'Theegarten et al.: Submesothelial deposition of carbon nanoparticles after toner exposition: Case report. Diagnostic Pathology 2010, 5:77'
نویسندگان
چکیده
A comment on ‘Theegarten et al.: Submesothelial deposition of carbon nanoparticles after toner exposition: Case report. Diagnostic Pathology 2010, 5:77’ We read with interest the article by Theegarten et al. [1] which reports on the case of a patient in whose peritoneum were found submesothial aggregates of carbon nanoparticles (CNPs) with a diameter of 31-67 nm. From their literature study and results the authors conclude that these CNPs must be particles emitted by a laser printer in an office environment and inhaled by the patient. In addition the abstract for [1] states: “Inhalation of CNP from toner dust has been shown to have impact on the respiratory health of persons exposed”. Other possible exposure and uptake paths for CNPs are not discussed in [1]. The paper by Theegarten et al. [1] includes experimental data on the morphology and on the constituents of the toner powder of a laser printer. This toner consists of particles with a diameter of 5-9 μm on whose surface “some small elevations” of metal oxides are found. The CNPs detected in the patient’s peritoneum were not, however, identified as toner constituents. In fact the assumption by Theegarten et al. that the CNPs detected in the patient’s peritoneum come from a laser printer is based solely on a reference to a study by Wensing et al. [2]. Theegarten et al. refer to [2] as follows: “Office printers were detected to emit carbon nanoparticles (CNP) in a variable extend”. As the authors of [2] we should like to note at this point that this statement is not correct. Our publication [2] does not contain any data which would point to CNPs being possible constituents of ultra-fine particles released from laser printers. Our chamber experiments were carried out in a clean and particle-free atmosphere. Therefore we can exclude influences from other sources and outdoor air. Indeed our article [2] states that the ultra-fine particles (UFPs) emitted from laser printers are volatile and are not original toner constituents ("toner dust”). The UFPs are rather formed by the nucleation and condensation processes of hydrophobic SVOCs (semi-volatile organic compounds) such as, for example, semi-volatile organic silicon compounds and higher aliphatic hydrocarbons [3,4]. The volatility of the UFPs which is also inconsistent with CNP as constituents of the UFPs was confirmed by VH-TDMA (volatilization and humidification tandem differential mobility analyzer) [4] and thermo denuder [3] measurements. We have never found CNPs in connection with laser printer experiments. Paper [4] is also cited in Theegarten et al. [1]. To sum up, it can be stated that our experimental data published in [2] and also in our later publications [3] and [4] do not in any way support the proposition that the patient in the present case was exposed to CNPs from laser printers.
منابع مشابه
Submesothelial deposition of carbon nanoparticles after toner exposition: Case report
Inhalation of carbon nanoparticles (CNP) from toner dust has been shown to have impact on the respiratory health of persons exposed. Office printers are known emitters of CNP. We report about a female open office worker who developed weight loss and diarrhoea. Laparoscopy done for suspected endometriosis surprisingly revealed black spots within the peritoneum. Submesothelial aggregates of CNP w...
متن کاملPrimary Localized Vesical Amyloidosis Mimicking Bladder Carcinoma: A Case Report
Amyloidosis of urinary bladder is a rare condition and may be primary or secondary in nature. A case of primary localized vesical amyloidosis (VA) in a 40-yr-old man is described confused with neoplasm by cystoscopic, urographic. Surgical specimens obtained by transurethral resection (TUR) were diagnostic and histologically revealed amyloid deposits in sub-epithelial stroma with chronic inflamm...
متن کاملComment on the Capstone Depleted Uranium (DU) Aerosol Characterization and Risk Assessment Study.
Dear Editors: WE NOTED that nowhere in the issue of Health Physics, March 2009, devoted to “The Capstone Depleted Uranium (DU) Aerosol Characterization and Risk Assessment Study” (Parkhurst and Guilmette 2009) were nanoparticles considered or even mentioned. The smallest particles considered were approximately 0.7 m in diameter (Holmes et al. 2009). Perhaps DU atoms may have entered the brain v...
متن کاملErratum for Mirhendi et al.,the first case of onychomycosis in a koala (phascolarctos cinereus) due to atypical isolates of Microsporum gypseum, a diagnostic challenge
Erratum for Mirhendi et al., the first case of onychomycosis in a koala (phascolarctos cinereus) due to atypical isolates of Microsporum gypseum, a diagnostic challenge Mirhendi H1,2*, Nishiyama Y3, Rezaei-Matehkolaei A4, Satoh K5, Makimura K5 1. Department of Medical Parasitology & Mycology, School of Medicine, Isfahan University of Medical Sciences, Isfahan, Iran 2. Department of Medi...
متن کاملSynthesis and purification of Carbon nanotubes
In this study, multi wall carbon nanotubes (MWCNTs) were synthesized by Chemical vapor deposition (CVD) method using two different catalysts (Fe nanoparticles) and (Ni nanoparticles) with two different substrates: Quartz and Alumina. Acetylene gas was used as a carbon source and Argon as a carrier gas at different temperatures and different times to study the effects of these parameters on CNT...
متن کامل