Small Lesion Detection with Resolution Enhancement Compression: a Method of Coded Excitation/pulse Compression by Paul Mitchell Linden
نویسنده
چکیده
A novel coded excitation method, resolution enhancement compression (REC), increases the axial resolution and the echo signal-to-noise ratio (eSNR) for an ultrasonic imaging system. The REC technique was examined for its ability to improve lesion detectability. In addition to lesion detectability, the REC technique was examined in the context of being peak voltage limited or peak pressure limited. The REC technique was used to double the –3-dB fractional pulse-echo bandwidth of an ultrasonic source in both simulations and experiments. The increase in usable bandwidth increased lesion detectability compared to conventional pulsing (CP) techniques and coded excitation using a linear chirp (LC). Lesion detectibility was quantified through lesion signal-to-noise ratio (lSNR), which is a metric that quantifies the ability of an isolated observer to detect a focal lesion against a background. In simulations, a higher lSNR value was observed using the pressure limited REC technique for lesions ranging in size from 1 mm to 8 mm in diameter. In addition, the eSNR was increased by almost 15 dB. Simulations also demonstrated that the voltage limited and the pressure limited form of REC outperformed the LC with respect to lSNR. To validate simulation results, a hydrogel cone phantom was constructed to provide lesions of different diameters with +6-dB contrast. A transducer was scanned perpendicular to the major axis of the cone at different levels to provide lesions of 3, 5, and 8 mm in diameter. The lSNR was estimated for lesions of different sizes and using the three excitation techniques, i.e., CP, LC, and REC. In experiments the lSNR was observed to be higher using the REC technique than the other pulsing techniques. The lSNR scores for REC were higher by 15%, 45%, and 40% for the 3, 5, and 8-mm as compared to the other two excitation iii techniques. The eSNR was increased by 5.7 dB. Therefore, according to the lSNR metric, the improvement in spatial resolution from the REC technique resulted in improved detectability of small lesions. iv Acknowledgments
منابع مشابه
An Ultrasonic Imaging Speckle Supression and Contrast Enhancement Technique by Means of Frequency Compounding and Coded Excitation
A method for improving the contrast resolution of B-mode images is proposed by combining the speckle reduction technique of frequency compounding (FC), and the coded excitation and pulse compression technique called resolution enhancement compression (REC). FC suppresses speckle but at the expense of a reduction in axial resolution. Using REC the axial resolution and bandwidth of the imaging sy...
متن کاملExtending the Radar Dynamic Range using Adaptive Pulse Compression
The matched filter in the radar receiver is only adapted to the transmitted signal version and its output will be wasted due to non-matching with the received signal from the environment. The sidelobes amplitude of the matched filter output in pulse compression radars are dependent on the transmitted coded waveforms that extended as much as the length of the code on both sides of the target loc...
متن کاملAssessment of Weighting Functions Used in Oppermann Codes in Polyphase Pulse Compression Radars
Polyphase is a common class of pulse compression waveforms in the radar systems. Oppermann code is one of the used codes with polyphone pattern. After compression, this code has little tolerant against Doppler shift in addition to its high side lobe level. This indicates that the use of Oppermann code is an unsuitable scheme to radars applications. This paper shows that the use of amplitude wei...
متن کاملClinical use and evaluation of coded excitation in B-mode images
Use of long encoded waveforms can be advantageous in ultra-sound imaging, as long as the pulse compression mechanism ensures low range sidelobes and preserves both axial resolution and contrast. A coded excitation/compression scheme was previously presented by our group, which is based on a predistorted FM excitation and a mismatched compression filter designed for medical ultrasonic applicatio...
متن کاملQuadratic Frequency Modulated Thermal Wave Imaging for Non-destructive Testing
Thermal non-destructive testing and evaluation of glass fibre reinforced plastic materials has gained more importance in aerospace industry due to low weight and high strength capabilities in severe environmental conditions. More recently, pulse compression favorable non-stationary excitation schemes have been exhibiting reliable defect detection capabilities in infrared non-destructive testing...
متن کامل