Improved stand for the donor eye for corneal grafting.

نویسنده

  • M H LUNTZ
چکیده

A STAND, developed at this hospital, for holding the donor eye while a corneal graft is trephined and dissected is particularly useful for lamellar, annular, or segmental grafts, especially where direct sutures are used (Fig. 1). Essentially this is a modified Tudor-Thomas stand, so designed as to rotate on a plinth carrying a spring-loaded metal ball (Fig. 2A), which engages consecutively into four notches placed at 900 intervals at the bottom of the stand (Fig. 2B). By this means the stand can be engaged at four positions 900 apart during one complete revolution. Disengagement from a "stop" requires no effort so that the entire mechanism works smoothly and efficiently. The plinth also has a pair of handles (Fig. 2c, c) with separate "lifters" for lifting it out of the sterilizer. B

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Risk Factors for Failure of Keratoplasty in Keratoconus: Penetrating vs. Deep Anterior Lamellar Keratoplasty

Purpose: To determine the etiologic factors on rejection and failure rates and ocular surface changes after corneal transplantation by either DALK or PKP, in cases of keratoconus (KCN). Methods: In this cross-sectional study, considering the existing data, patients with keratoconus referring to Labbafinejad Medical Center from 2006 to 2016, who underwent corneal transplantation, were enrolled a...

متن کامل

Patch Grafting Using a Cryopreserved Descemet Stripping Automated Endothelial Keratoplasty Flap for Treating Corneal Perforation

A 73-year-old woman with a corneal perforation of undetermined etiology was treated with corneal patch grafting. A residual partial-thickness corneal button obtained during a previous Descemet stripping automated endothelial keratoplasty (DSAEK) surgery and stored at -80°C in Optisol GS for 3 months was used as a patch graft. Five days postoperatively, the anterior chamber was reformed and the ...

متن کامل

بررسی اصلاح قوز قرنیه با استفاده از قطعات ‏حلقوی داخل قرنیه‌ای فرارا

  Background and Objective: Evaluation of the results, safety, and stability of ferrara intracorneal ring segment (FICRS) implantation for Keratoconus correction (age range was 24.39±8.32 years).   Materials and Methods: In this clinical trial study, 64 eyes of 57 patients with keratoconus and clear cornea that had FICRS implantation were studied. Uncorrected visual acuity (UCVA), best-spectacl...

متن کامل

Attachment for a Tudor Thomas corneal graft stand.

DONOR material for corneal grafting is not readily available. In exploring all sources, it was thought that one could use material which would otherwise be wasted if it were possible to cut satisfactory lamellar grafts from excised corneae. The attachment to be described is the result of experiments conducted with this purpose in view. The idea originated from a desire to use corneae from eyes ...

متن کامل

Successful Treatment of Postkeratoplasty Fungal Keratitis with Topical and Intrastromal Voriconazole

Objective: Corneal grafts have a major risk of fungal keratitis due to long-term local and sometimes systemic steroid/antibiotic use. The aim of this study was to evaluate the efficacy of intrastromal voriconazole as a therapeutic adjunctive for the management of fungal keratitis in corneal graft. Design: Presentation of two cases of fungal keratitis occurring after corneal transplantation and ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The British journal of ophthalmology

دوره 44  شماره 

صفحات  -

تاریخ انتشار 1960