چکیده
X-ray grating interferometry is a promising imaging technique sensitive to attenuation, refraction and scattering of the radiation. Applications of this technique in the energy range between 80 and 150 keV pose severe technical challenges, and are still mostly unexplored. Phase-contrast X-ray imaging at such high energies is of relevant scientific and industrial interest, in particular for the investigation of strongly absorbing or thick materials as well as for medical imaging. Here we show the successful implementation of a Talbot-Lau interferometer operated at 100 keV using a conventional X-ray tube and a compact geometry, with a total length of 54 cm. We present the edge-on illumination of the gratings in order to overcome the current fabrication limits. Finally, the curved structures match the beam divergence and allow a large field of view on a short and efficient setup.
منابع مشابه
Development of microperiodic mirrors for hard x-ray phase-contrast imaging.
Differential phase-contrast imaging with hard x rays can have important applications in medicine, material sciences, and energy research. Phase-contrast methods based on microperiodic optics, such as shearing interferometry, are particularly attractive because they allow the use of conventional x-ray tubes. To enable shearing interferometry with x rays up to 100?keV, we propose using grazing-in...
متن کاملHigh-resolution X-ray imaging for lab-based materials research
The extension of limits of X-ray imaging techniques – in terms of spatial and temporal resolution as well as of material contrast – in the energy range from 5 to 70 keV has long exclusively taken place at third generation synchrotron beamlines. Yet, by using the latest generation of lab-sources together with novel X-ray detectors, results from microas well as sub-micrometer imaging are obtained...
متن کاملX-ray phase contrast imaging of biological specimens with tabletop synchrotron radiation
The x-ray tube is still the most common source of x-rays, but cutting-edge medical applications demand high quality beams of x-rays, the production of which often requires large, expensive synchrotron x-ray facilities. Our scheme deploys a recently demonstrated tabletop source of 1-100 keV synchrotron radiation. Here, in order to produce high quality x-rays, electrons are accelerated and wiggle...
متن کاملImaging by using proton-induced quasi- monochromatic X-ray emission
Quasi-monochromatic X-ray emission induced by MeV-proton bombardment onto metallic targets was applied to radiography of small samples. The X-ray energy was adjusted in the range of z4–23 keV by changing the target material. The radiograms were recorded on an imaging plate. A small phantom made of Lucite was prepared for the test of photography using a contrast medium (RuCl3$H2O; ruthenium chlo...
متن کاملTranslation of Atherosclerotic Plaque Phase-Contrast CT Imaging from Synchrotron Radiation to a Conventional Lab-Based X-Ray Source
OBJECTIVES Phase-contrast imaging is a novel X-ray based technique that provides enhanced soft tissue contrast. The aim of this study was to evaluate the feasibility of visualizing human carotid arteries by grating-based phase-contrast tomography (PC-CT) at two different experimental set-ups: (i) applying synchrotron radiation and (ii) using a conventional X-ray tube. MATERIALS AND METHODS Fi...