Automated Calculation of Water‐equivalent Diameter (DW) Based on AAPM Task Group 220

نویسندگان

  • Choirul Anam
  • Freddy Haryanto
  • Rena Widita
  • Idam Arif
  • Geoff Dougherty
چکیده

The purpose of this study is to accurately and effectively automate the calculation of the water-equivalent diameter (DW) from 3D CT images for estimating the size-specific dose. DW is the metric that characterizes the patient size and attenuation. In this study, DW was calculated for standard CTDI phantoms and patient images. Two types of phantom were used, one representing the head with a diameter of 16 cm and the other representing the body with a diameter of 32 cm. Images of 63 patients were also taken, 32 who had undergone a CT head examination and 31 who had undergone a CT thorax examination. There are three main parts to our algorithm for automated DW calculation. The first part is to read 3D images and convert the CT data into Hounsfield units (HU). The second part is to find the contour of the phantoms or patients automatically. And the third part is to automate the calculation of DW based on the automated contouring for every slice (DW,all). The results of this study show that the automated calculation of DW and the manual calculation are in good agreement for phantoms and patients. The differences between the automated calculation of DW and the manual calculation are less than 0.5%. The results of this study also show that the estimating of DW,all using DW,n=1 (central slice along longitudinal axis) produces percentage differences of -0.92% ± 3.37% and 6.75%± 1.92%, and estimating DW,all using DW,n=9 produces percentage differences of 0.23% ± 0.16% and 0.87% ± 0.36%, for thorax and head examinations, respectively. From this study, the percentage differences between normalized size-specific dose estimate for every slice (nSSDEall) and nSSDEn=1 are 0.74% ± 2.82% and -4.35% ± 1.18% for thorax and head examinations, respectively; between nSSDEall and nSSDEn=9 are 0.00% ± 0.46% and -0.60% ± 0.24% for thorax and head examinations, respectively.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of AAPM Reports 204 and 220: Estimation of effective diameter, water‐equivalent diameter, and ellipticity ratios for chest, abdomen, pelvis, and head CT scans

PURPOSE To confirm AAPM Reports 204/220 and provide data for the future expansion of these reports by: (a) presenting the first large-scale confirmation of the reports using clinical data, (b) providing the community with size surrogate data for the head region which was not provided in the original reports, and additionally providing the measurements of patient ellipticity ratio for different ...

متن کامل

Use of Water Equivalent Diameter for Calculating Patient Size and Size-Specific Dose Estimates (SSDE) in CT: The Report of AAPM Task Group 220.

DISCLAIMER: This publication is based on sources and information believed to be reliable, but the AAPM, the authors, and the editors disclaim any warranty or liability based on or relating to the contents of this publication. The AAPM does not endorse any products, manufacturers , or suppliers. Nothing in this publication should be interpreted as implying such endorsement. 12 DISCLAIMER: This p...

متن کامل

Automatic calculation of patient size metrics in computed tomography: What level of computational accuracy do we need?

OBJECTIVES To compare the effectiveness of two different patient size metrics based on water equivalent diameter (Dw ), the mid-scan water equivalent diameter Dw_c , and the mean (average) water equivalent diameter in the imaged region, Dw_ave , for automatic detection of accidental changes in computed tomography (CT) acquisition protocols. METHODS Patient biometric data (height and weight) w...

متن کامل

Dose calculation formalisms and consensus dosimetry parameters for intravascular brachytherapy dosimetry: recommendations of the AAPM Therapy Physics Committee Task Group No. 149.

Since the publication of AAPM Task Group 60 report in 1999, a considerable amount of dosimetry data for the three coronary brachytherapy systems in use in the United States has been reported. A subgroup, Task Group 149, of the AAPM working group on Special Brachytherapy Modalities (Bruce Thomadsen, Chair) was charged to develop recommendations for dose calculation formalisms and the related con...

متن کامل

A Comparison of dosimetric parameters between IAEA TRS-398, AAPM TG-51 protocols and Monte-Carlo simulation

Background: Two protocols of AAPM TG-51 and IAEA TRS-398 were compared followed by a measurement and Monte Carlo simulation of beam quality correction factor, KQ, AAPM TG-51 and IAEA TRS-398 protocols were compared for the absorbed dose to water for DW, and KQ parameters. Materials and Methods: Dose measurements by either protocols were performed with cylindrical and plane parallel ch...

متن کامل